Improved Dosimetry for Yttrium-90 Microsphere Treatments of Liver Malignancies
Yttrium-90 (90Y) microspheres are used for the treatment of non-resectable liver cancer. The treatment has shown promising results, including the potential to downgrade the disease state to resectable. However, there is presently no U.S. national standard measurement device used for the determinatio...
Saved in:
Main Author | |
---|---|
Format | Dissertation |
Language | English |
Published |
ProQuest Dissertations & Theses
01.01.2012
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Yttrium-90 (90Y) microspheres are used for the treatment of non-resectable liver cancer. The treatment has shown promising results, including the potential to downgrade the disease state to resectable. However, there is presently no U.S. national standard measurement device used for the determination of 90Y microsphere activity. A coincidence detection system (CDS) was developed to spectroscopically assay the activity of 90Y microspheres by detecting the coincident 511 keV annihilation photons present in a 90Y photon spectrum due to the internal pair production component of 90Y decay. The CDS paired a HPGe detector with a large NaI detector. A method for correcting for counting losses that utilized a series of pulse generators was implemented into the CDS and validated. The geometric sensitivity of the CDS was characterized, and the system was shown to be able to accurately determine the activity of 90Y sources. The system was used to determine the activity of a sample of resin 90Y microspheres. Two well-type ionization chambers were characterized for their response to 90Y sources to investigate their use for the clinical determination of 90Y microspheres activity. The activity preparation methods used with the resin 90Y microspheres were investigated, and the effects of the volume dependencies of the ionization chambers on the activity delivered were analyzed. Based the results of the analysis, recommendations for measurement geometries that provided more accurate activity determinations were suggested. The effects of the microsphere and surrounding material on the 90Y dose kernel were studied with Monte Carlo transport codes MCNP5 and EGSnrc. The microsphere material was found to have little effect on the dose kernel, but the density of the surrounding material was found to greatly affect the calculated dose kernel. The developed CDS was shown to be a possible standard activity measurement device for 90Y microspheres. This work determined that well-type ionization chambers could be calibrated using sources whose activities had been determined with the CDS, for the accurate determination of 90Y microsphere activity in a clinical setting. Establishing a calibration service based on this work would help reduce the uncertainty in the dosimetry associated with the 90Y microsphere treatment. |
---|---|
ISBN: | 9781267431271 126743127X |