MIRD Pamphlet No. 17: The Dosimetry of Nonuniform Activity Distributions--Radionuclide S Values at the Voxel Level

The availability of quantitative three-dimensional in vivo data on radionuclide distributions within the body makes it possible to calculate the corresponding nonuniform distribution of radiation absorbed dose in body organs and tissues. This pamphlet emphasizes the utility of the MIRD schema for su...

Full description

Saved in:
Bibliographic Details
Published inThe Journal of nuclear medicine (1978) Vol. 40; no. 1; pp. 11S - 36S
Main Authors Bolch, Wesley E, Bouchet, Lionel G, Robertson, James S, Wessels, Barry W, Siegel, Jeffry A, Howell, Roger W, Erdi, Alev K, Aydogan, Bulent, Costes, Sylvain, Watson, Evelyn E, In collaboration with MIRD Committee, Society of Nuclear Medicine: E.E. Watson (Chair), J.S. Robertson (Task Group Leader), W.E. Bolch, A.B. Brill, N.D. Charkes, D.R. Fisher, M.T. Hays, R.W. Howell, J.A. Siegel, S.R. Thomas and B.W. Wessels
Format Journal Article
LanguageEnglish
Published Reston, VA Soc Nuclear Med 01.01.1999
Society of Nuclear Medicine
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The availability of quantitative three-dimensional in vivo data on radionuclide distributions within the body makes it possible to calculate the corresponding nonuniform distribution of radiation absorbed dose in body organs and tissues. This pamphlet emphasizes the utility of the MIRD schema for such calculations through the use of radionuclide S values defined at the voxel level. The use of both dose point-kernels and Monte Carlo simulation methods is also discussed. PET and SPECT imaging can provide quantitative activity data in voxels of several millimeters on edge. For smaller voxel sizes, accurate data cannot be obtained using present imaging technology. For submillimeter dimensions, autoradiographic methods may be used when tissues are obtained through biopsy or autopsy. Sample S value tabulations for five radionuclides within cubical voxels of 3 mm and 6 mm on edge are given in the appendices to this pamphlet. These S values may be used to construct three-dimensional dose profiles for nonuniform distributions of radioactivity encountered in therapeutic and diagnostic nuclear medicine. Data are also tabulated for 131I in 0.1-mm voxels for use in autoradiography. Two examples illustrating the use of voxel S values are given, followed by a discussion of the use of three-dimensional dose distributions in understanding and predicting biologic response.
ISSN:0161-5505
1535-5667