An approach to model shaft voltage of wound rotor synchronous machines
In the case of high power synchronous machines, shaft voltage can induce high currents yielding to bearing damages but it can also constitutes a variable to be used to diagnosis some machine defects. Therefore, it is important to well model the phenomenon in order to use it in further diagnosis tool...
Saved in:
Published in | 2016 IEEE Conference on Electromagnetic Field Computation (CEFC) p. 1 |
---|---|
Main Authors | , , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.11.2016
|
Subjects | |
Online Access | Get full text |
DOI | 10.1109/CEFC.2016.7816291 |
Cover
Loading…
Summary: | In the case of high power synchronous machines, shaft voltage can induce high currents yielding to bearing damages but it can also constitutes a variable to be used to diagnosis some machine defects. Therefore, it is important to well model the phenomenon in order to use it in further diagnosis tool. |
---|---|
DOI: | 10.1109/CEFC.2016.7816291 |