INVESTIGATION OF [beta]-EMISSION METHODS OF MONITORING COOLANT WATER LEVEL IN NUCLEAR POWER PLANTS

This investigation was performed on a vessel heat-engineering bench. The working medium was water under pressure up to it 20.5 MPa and temperature from 20 (cold) to 350[degrees]C (hot). The controllers were a [beta]-emission sensor of level and a Sapfir-22DD differential manometer as the standard. T...

Full description

Saved in:
Bibliographic Details
Published inAtomic energy (New York, N.Y.) Vol. 122; no. 3; pp. 207 - 212
Main Authors Aleksandrov, S.I, Bolshov, A.A, Kornienko, A.V, Novikov, I.V, Postnikov, V.V, Shishov, V.P, Yurkin, G.V
Format Journal Article
LanguageEnglish
Published Springer 01.07.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This investigation was performed on a vessel heat-engineering bench. The working medium was water under pressure up to it 20.5 MPa and temperature from 20 (cold) to 350[degrees]C (hot). The controllers were a [beta]-emission sensor of level and a Sapfir-22DD differential manometer as the standard. The objective was to determine the characteristics of a [beta]-emission sensor under the conditions of the working medium. Analysis of the experimental data showed that the indications of the [beta]-emission sensor and differential manometer were identical and linear as a function of the level of both the cold and hot water. The characteristics of the [beta]-emission sensor are: minimal response time and measurement error, very small dimensions, serviceability at pressures to 20.5 MPa and temperature to 350[degrees]C, at least 10 years life, and energy independence of the primary converter.
ISSN:1063-4258
1573-8205