Converting a Commercial Distillation Column into a Research Tower
For the first set of test runs, additional changes were made to the tower internals. ULTRA-FRAC trays have astonishingly high capacities. In the 1992 column revamp from dual-flow to ULTRA-FRAC trays, the tower was equipped with six elements per tray. The reboiler was incapable of flooding such a tow...
Saved in:
Published in | Chemical engineering progress Vol. 101; no. 7; pp. 41 - 46 |
---|---|
Main Authors | , , |
Format | Magazine Article Journal Article |
Language | English |
Published |
New York
American Institute of Chemical Engineers
01.07.2005
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | For the first set of test runs, additional changes were made to the tower internals. ULTRA-FRAC trays have astonishingly high capacities. In the 1992 column revamp from dual-flow to ULTRA-FRAC trays, the tower was equipped with six elements per tray. The reboiler was incapable of flooding such a tower (and the condenser would have been incapable of condensing the vapor, if it could have been flooded). |
---|---|
Bibliography: | content type line 24 ObjectType-Feature-1 SourceType-Magazines-1 ObjectType-Article-2 SourceType-Scholarly Journals-1 content type line 23 |
ISSN: | 0360-7275 1945-0710 |