Electrochemical characterisation of X10CrNi 18-8 steel in artificial plasma
Quality of applied guide wires conditions the course of treatment and its success to a great extent. In order to simulate conditions that can be found in blood vascular system samples were exposed to artificial blood plasma (T = 37 } 1 oC) for the time of 8 h. In order to obtain information regardin...
Saved in:
Published in | Metalurgija Vol. 54; no. 1; pp. 63 - 66 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
Croatian Metallurgical Society
01.01.2015
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Quality of applied guide wires conditions the course of treatment and its success to a great extent. In order to simulate conditions that can be found in blood vascular system samples were exposed to artificial blood plasma (T = 37 } 1 oC) for the time of 8 h. In order to obtain information regarding physical and chemical properties of modified surface of wire made of X10CrNi 18-8 steel, electrochemical impedance spectroscopy (EIS) test and tests of chemical composition of the surface layer X-ray photoelectron spectroscopy (XPS) were made. On the ground of performed EIS and XPS tests, favourable impact of steam sterilisation process on corrosion resistance of X10CrNi 18-8 steel was observed only for the case when chemical passivation was applied prior to sterilisation. |
---|---|
ISSN: | 0543-5846 1334-2576 |