CALCULATION AND ANALYSIS OF INHERENT FREQUENCY FOR HIGH-SPEED DRY GAS SEAL TEST BENCH ROTOR

In order to avoid the design of the rotor of the dry gas seal high speed test stand occur resonance phenomenon during high speed running,the transfer matrix method was applicated to calculate the natural frequency.Then it obtains that its natural frequency is 14044.586r/min when the dry gas seal sta...

Full description

Saved in:
Bibliographic Details
Published inJi xie qiang du Vol. 39; pp. 761 - 765
Main Authors DING XueXing, WU YuanYuan, ZHANG WeiZheng, ZHAI Xiao, LU JunJie
Format Journal Article
LanguageChinese
Published Editorial Office of Journal of Mechanical Strength 15.08.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In order to avoid the design of the rotor of the dry gas seal high speed test stand occur resonance phenomenon during high speed running,the transfer matrix method was applicated to calculate the natural frequency.Then it obtains that its natural frequency is 14044.586r/min when the dry gas seal static and ring `s quality is 33.78 kg in rotor system,and using the finite element method analysis the modes of the rotor system when it is operating in the vicinity of its natural frequency,then it will get the modal figure with four modal value.Comparative and analysis the results of the two methods,though simplified model are not the same,the results are similar.And the design of speed can meet the requirements,so it can describe the design of the rotor system is reasonable.
ISSN:1001-9669
DOI:10.16579/j.issn.1001.9669.2017.04.003