Reproducibility of Digital Planning in Cementless Total Hip Arthroplasty Among Experienced and Novice Surgeons

The present study aims to assess the reproducibility of digital planning for cementless total hip arthroplasty (THA) among surgeons with different levels of experience. In addition, it attempts to determine the degree of planning reliability based on a contralateral THA or on a spherical marker posi...

Full description

Saved in:
Bibliographic Details
Published inRevista brasileira de ortopedia Vol. 58; no. 2; pp. 246 - 251
Main Authors Fabricio, Marcelo Zerbetto, Rudelli, Bruno Alves, Miyahara, Helder de Souza, Ejnisman, Leandro, Gurgel, Henrique de Melo Campos, Croci, Alberto Tesconi
Format Journal Article
LanguageEnglish
Portuguese
Published Germany Sociedade Brasileira de Ortopedia e Traumatologia 01.04.2023
Thieme Revinter Publicações Ltda
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The present study aims to assess the reproducibility of digital planning for cementless total hip arthroplasty (THA) among surgeons with different levels of experience. In addition, it attempts to determine the degree of planning reliability based on a contralateral THA or on a spherical marker positioned at the greater trochanter for calibration.  Two evaluators with different experience levels (A1 and A2) performed independently the retrospective digital surgical planning of 64 cementless THAs. Next, we compared the planning with the implants used in the surgery. The reproducibility was excellent when planning and implants were identical; proper in case of a single-unit variation; and inappropriate if there was variation in two or more units. The present analysis also determined the calibration accuracy between the contralateral THA and the spherical marker at the greater trochanter level.  The present study demonstrated greater success when the most experienced evaluator performed the planning and greater accuracy for the contralateral THA. When splitting the analysis per parameter (contralateral THA or spherical marker), there was a statistical difference only for the planning of A1 and the implants used in the surgery. This difference occurred in the excellent category, with 67.3% for contralateral THA compared with 30.6% for a spherical marker ( <0.001), and in the inappropriate category, with 7.1% for contralateral THA compared with 30.6% for a spherical marker ( <0.001).  Digital planning is more accurate when performed by an experienced evaluator. The contralateral prosthesis head was a better reference than a marker on the greater trochanter.
ISSN:0102-3616
1982-4378
1982-4378
DOI:10.1055/s-0042-1750758