Contrast-Enhanced Ultrasound Quantification Assessment of Focal Fatty Variations in Liver Parenchyma: Challenging the Traditional Qualitative Paradigm of Uniform Enhancement With Adjacent Parenchyma
The purpose of this study was to quantify contrast-enhanced ultrasound enhancement of focal fatty sparing (FFS) and focal fatty infiltration (FFI) and compare it with adjacent liver parenchyma. This was a retrospective observational study yielding 42 cases in the last 4 years. Inclusion criteria wer...
Saved in:
Published in | Journal of ultrasound in medicine Vol. 40; no. 6; pp. 1137 - 1145 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
England
01.06.2021
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The purpose of this study was to quantify contrast-enhanced ultrasound enhancement of focal fatty sparing (FFS) and focal fatty infiltration (FFI) and compare it with adjacent liver parenchyma.
This was a retrospective observational study yielding 42 cases in the last 4 years. Inclusion criteria were a focal liver lesion, adequate video availability, and an established diagnosis of FFS or FFI based on clinical or imaging follow-up or a second modality. Contrast-enhanced ultrasound examinations were performed with a standard low-mechanical index technique. Commercially available software calculated quantitative parameters for a focal liver lesion and a reference area of liver parenchyma, producing relative indices.
In total, 42 patients were analyzed (19 male) with a median age of 18 (interquartile range, 42) years and a median lesion diameter of 30 (interquartile range, 16) mm. The cohort included 26 with FFS and 16 with FFI. Subjectively assessed, 27% of FFS and 25% of FFI were hypoenhancing in the arterial phase, and 73% of FFS and 75% of FFI were isoenhancing. In the venous and delayed phases, all lesions were isoenhancing. The peak enhancement (P = .001), wash-in area under the curve (P < .01), wash-in rate (P = .023), and wash-in perfusion index (P = .001) were significantly lower in FFS compared with adjacent parenchyma but not the mean transit time. In the FFI subgroup, no significant difference was detected. Comparing relative parameters, only the wash-in rate was significantly (P = .049) lower in FFS than FFI. The mean follow-up was 2.8 years.
Focal fatty sparing shows significantly lower and slower enhancement than the liver parenchyma, whereas FFI enhances identically. Focal fatty sparing had a significantly slower enhancement than FFI. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Undefined-1 ObjectType-Feature-3 content type line 23 |
ISSN: | 0278-4297 1550-9613 |
DOI: | 10.1002/jum.15494 |