Calculation of Exergy Destruction of Various Components by Performing Exergy Analysis on Stage-I of Dr. Narla Tatarao Thermal Power Station N.T.T.P.S

For any nation to develop power generation plays a crucial role. The performance of a power plant is analyzed by using the Energy balance and it is done by using the first law of thermodynamics. But to know how much energy is being utilized in reality exergy analysis has to be performed which is als...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of engineering and advanced technology Vol. 9; no. 2; pp. 1196 - 1200
Main Authors Varun, N Naga, Reddy, T Subba, Kumar, T L Prasannna, Mithra, S P Krishna, Reddy, M Srinivasa
Format Journal Article
LanguageEnglish
Published 30.12.2019
Online AccessGet full text

Cover

Loading…
More Information
Summary:For any nation to develop power generation plays a crucial role. The performance of a power plant is analyzed by using the Energy balance and it is done by using the first law of thermodynamics. But to know how much energy is being utilized in reality exergy analysis has to be performed which is also called as second law of thermodynamic analysis because the vital parameter quality is being considered in the exergy analysis. this paper deals with the exergy destruction calculation by performing exergy analysis for various components for a 210 mw plant of Vijayawada thermal power station(stage-1 unit-1) and from the analysis it is clear that exergy destruction is more in condenser
ISSN:2249-8958
2249-8958
DOI:10.35940/ijeat.B3539.129219