Highest Resolution In Vivo Human Brain MRI Using Prospective Motion Correction

High field MRI systems, such as 7 Tesla (T) scanners, can deliver higher signal to noise ratio (SNR) than lower field scanners and thus allow for the acquisition of data with higher spatial resolution, which is often demanded by users in the fields of clinical and neuroscientific imaging. However, h...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 10; no. 7; p. e0133921
Main Authors Stucht, Daniel, Danishad, K. Appu, Schulze, Peter, Godenschweger, Frank, Zaitsev, Maxim, Speck, Oliver
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 30.07.2015
Public Library of Science (PLoS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:High field MRI systems, such as 7 Tesla (T) scanners, can deliver higher signal to noise ratio (SNR) than lower field scanners and thus allow for the acquisition of data with higher spatial resolution, which is often demanded by users in the fields of clinical and neuroscientific imaging. However, high resolution scans may require long acquisition times, which in turn increase the discomfort for the subject and the risk of subject motion. Even with a cooperative and trained subject, involuntary motion due to heartbeat, swallowing, respiration and changes in muscle tone can cause image artifacts that reduce the effective resolution. In addition, scanning with higher resolution leads to increased sensitivity to even very small movements. Prospective motion correction (PMC) at 3T and 7T has proven to increase image quality in case of subject motion. Although the application of prospective motion correction is becoming more popular, previous articles focused on proof of concept studies and technical descriptions, whereas this paper briefly describes the technical aspects of the optical tracking system, marker fixation and cross calibration and focuses on the application of PMC to very high resolution imaging without intentional motion. In this study we acquired in vivo MR images at 7T using prospective motion correction during long acquisitions. As a result, we present images among the highest, if not the highest resolution of in vivo human brain MRI ever acquired.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Commentary-3
content type line 23
Competing Interests: The department receives research support from Siemens Healthcare and Kineticor. This does not alter the authors’ adherence to PLOS ONE policies on sharing data and materials.
Conceived and designed the experiments: DS KAD PS FG OS. Performed the experiments: DS KAD PS FG. Analyzed the data: DS KAD. Contributed reagents/materials/analysis tools: DS FG MZ. Wrote the paper: DS KAD. Revised manuscript: DS KAD PS OS.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0133921