Comparison of nasopharyngeal and oropharyngeal swabs for the diagnosis of eight respiratory viruses by real-time reverse transcription-PCR assays

Many acute respiratory illness surveillance systems collect and test nasopharyngeal (NP) and/or oropharyngeal (OP) swab specimens, yet there are few studies assessing the relative measures of performance for NP versus OP specimens. We collected paired NP and OP swabs separately from pediatric and ad...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 6; no. 6; p. e21610
Main Authors Kim, Curi, Ahmed, Jamal A, Eidex, Rachel B, Nyoka, Raymond, Waiboci, Lilian W, Erdman, Dean, Tepo, Adan, Mahamud, Abdirahman S, Kabura, Wamburu, Nguhi, Margaret, Muthoka, Philip, Burton, Wagacha, Breiman, Robert F, Njenga, M Kariuki, Katz, Mark A
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 30.06.2011
Public Library of Science (PLoS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Many acute respiratory illness surveillance systems collect and test nasopharyngeal (NP) and/or oropharyngeal (OP) swab specimens, yet there are few studies assessing the relative measures of performance for NP versus OP specimens. We collected paired NP and OP swabs separately from pediatric and adult patients with influenza-like illness or severe acute respiratory illness at two respiratory surveillance sites in Kenya. The specimens were tested for eight respiratory viruses by real-time reverse transcription-polymerase chain reaction (qRT-PCR). Positivity for a specific virus was defined as detection of viral nucleic acid in either swab. Of 2,331 paired NP/OP specimens, 1,402 (60.1%) were positive for at least one virus, and 393 (16.9%) were positive for more than one virus. Overall, OP swabs were significantly more sensitive than NP swabs for adenovirus (72.4% vs. 57.6%, p<0.01) and 2009 pandemic influenza A (H1N1) virus (91.2% vs. 70.4%, p<0.01). NP specimens were more sensitive for influenza B virus (83.3% vs. 61.5%, p = 0.02), parainfluenza virus 2 (85.7%, vs. 39.3%, p<0.01), and parainfluenza virus 3 (83.9% vs. 67.4%, p<0.01). The two methods did not differ significantly for human metapneumovirus, influenza A (H3N2) virus, parainfluenza virus 1, or respiratory syncytial virus. The sensitivities were variable among the eight viruses tested; neither specimen was consistently more effective than the other. For respiratory disease surveillance programs using qRT-PCR that aim to maximize sensitivity for a large number of viruses, collecting combined NP and OP specimens would be the most effective approach.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Conceived and designed the experiments: RBE MAK JAA MKN WB RB ASM PM. Performed the experiments: RBE MAK JAA AT ASM WK MN MKN DE LWW PM WB. Analyzed the data: RN CK MAK RBE MKN JAA RFB LWW. Contributed reagents/materials/analysis tools: DE MKN LWW. Wrote the paper: CK MAK RBE JAA DE RFB LWW MKN RN.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0021610