Refractive Status in Eyes Implanted with Toric and Nontoric Intraocular Lenses during Combined Cataract Surgery and Microhook Ab Interno Trabeculotomy

Purpose. To compare the refractive status between eyes implanted with toric and nontoric intraocular lenses (IOLs) during combined cataract surgery and microhook ab interno trabeculotomy (μLOT), a minimally invasive glaucoma surgery (MIGS). Methods. Twenty eyes of 20 patients who had open-angle glau...

Full description

Saved in:
Bibliographic Details
Published inJournal of ophthalmology Vol. 2021; pp. 5545007 - 7
Main Authors Takai, Yasuyuki, Sugihara, Kazunobu, Mochiji, Mihoko, Manabe, Kaoru, Tsutsui, Aika, Tanito, Masaki
Format Journal Article
LanguageEnglish
Published United States Hindawi 2021
John Wiley & Sons, Inc
Hindawi Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose. To compare the refractive status between eyes implanted with toric and nontoric intraocular lenses (IOLs) during combined cataract surgery and microhook ab interno trabeculotomy (μLOT), a minimally invasive glaucoma surgery (MIGS). Methods. Twenty eyes of 20 patients who had open-angle glaucoma, cataract, and preexisting regular corneal astigmatism exceeding 1.5 diopters (D) and underwent combined μLOT and phacoemulsification were recruited retrospectively. Ten eyes were implanted with a toric IOL and 10 eyes with a nontoric IOL. The primary outcomes were the uncorrected visual acuity (UCVA) and refractive cylinder at 3 months postoperatively. Results. The mean UCVA of the toric IOL group (logarithm of the minimum angle of resolution (logMAR), 0.23 ± 0.25) was significantly better than that of the nontoric IOL group (logMAR, 0.45 ± 0.26) at 3 months postoperatively (p<0.05). The mean absolute residual refractive cylinder of the nontoric IOL group (2.25 ± 0.62 D) was significantly greater than that of the toric IOL group (1.30 ± 0.68 D) (p<0.05). Postoperatively, 60% of eyes in the toric IOL group and 10% in the nontoric IOL group had an absolute refractive astigmatism level of 1.5 D or less. Surgically induced astigmatism (0.77 ± 0.43 D for toric group and 0.60 ± 0.32 D for nontoric group) and IOP reduction (33.9 ± 15.6% for toric group and 29.4 ± 11.7% for nontoric group) were not different between groups. Conclusions. Use of toric IOL during combined cataract surgery and μLOT is possible and better than not, but physician should prevent their patient of persisting residual astigmatism. The study was registered at https://www.umin.ac.jp/, and the clinical trial accession number is https://clinicaltrials.gov/ct2/show/UMIN000043141.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Academic Editor: Zisis Gatzioufas
ISSN:2090-004X
2090-0058
DOI:10.1155/2021/5545007