Three-dimensional/four-dimensional spatiotemporal image correlation morphology of the ductus arteriosus in fetuses with pulmonary atresia undergoing neonatal ductal stenting

ABSTRACT Background: The value of prenatal identification of morphology of ductus arteriosus in fetuses with congenital heart defects (CHD) with pulmonary atresia and duct-dependent pulmonary circulation (DDPC) in planning neonatal ductal stenting procedure is untested. The aim of the study is to an...

Full description

Saved in:
Bibliographic Details
Published inAnnals of pediatric cardiology Vol. 16; no. 4; pp. 233 - 241
Main Authors Karapurkar, Sonia, Gurav, Aishwarya, Sudhakar, Abish, Sasikumar, Navaneetha, Kumar, Raman Krishna, Vaidyanathan, Balu
Format Journal Article
LanguageEnglish
Published India Wolters Kluwer - Medknow 01.07.2023
Medknow Publications and Media Pvt. Ltd
Medknow Publications & Media Pvt. Ltd
Wolters Kluwer Medknow Publications
Edition2
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:ABSTRACT Background: The value of prenatal identification of morphology of ductus arteriosus in fetuses with congenital heart defects (CHD) with pulmonary atresia and duct-dependent pulmonary circulation (DDPC) in planning neonatal ductal stenting procedure is untested. The aim of the study is to analyze the utility of three-dimensional/four-dimensional (3D/4D) spatiotemporal image correlation (STIC) fetal echocardiography in delineating the morphology of ductus arteriosus in fetuses with DDPC undergoing neonatal ductal stenting. Methods: In this retrospective study (2017-22), prenatal imaging of pulmonary artery (PA) anatomy, aortic arch sidedness, and morphology of ductus arteriosus (ductal origin was classified as vertical/horizontal and ductal course as tortuous/straight) was done using 3D/4D STIC imaging and volume datasets. Prenatal findings were correlated with angiographic findings during stenting and the degree of agreement was calculated. Results: We included 27 fetuses with a prenatal diagnosis of CHD with DDPC who underwent neonatal ductal stenting. The accuracy of prenatal assessment of PA anatomy, branch PA stenosis, and arch sidedness was 100%, 92.6%, and 88.9%, respectively. The accuracy of prenatal assessment of ductal origin and course, compared with angiography, was 85.2% and 88.9%, respectively. Prenatal imaging had a diagnostic accuracy of 100% for vertical straight and horizontal tortuous ducts, 84.6% for vertical tortuous, and 67% for horizontal straight ducts. Duct stenting was successful in 25 (92.6%) babies; two died after the procedure from stent occlusion. Conclusion: Fetal echocardiography using 3D/4D STIC imaging enables accurate delineation of the morphology of ductus arteriosus in fetuses with DDPC, thereby aiding parental counseling and planning neonatal ductal stenting.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0974-2069
0974-5149
DOI:10.4103/apc.apc_95_23