Repeatability and Reproducibility of a Double-Pass Optical Quality Analysis Device

To evaluate the repeatability and reproducibility of a double-pass instrument (OQASII, Visiomereics SL, Spain), which objectively measures overall optical quality of the human eyes. The right eye of 119 healthy subjects with best corrected visual acuity of 20/25 or better was included in this prospe...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 10; no. 2; p. e0117587
Main Authors Xu, Chen-Chen, Xue, Ting, Wang, Qin-Mei, Zhou, Yi-Ni, Huang, Jin-Hai, Yu, A-Yong
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 03.02.2015
Public Library of Science (PLoS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To evaluate the repeatability and reproducibility of a double-pass instrument (OQASII, Visiomereics SL, Spain), which objectively measures overall optical quality of the human eyes. The right eye of 119 healthy subjects with best corrected visual acuity of 20/25 or better was included in this prospective, comparative, observational study. Two separate tests with OQASII were conducted sequentially on the same day by two different examiners. A week later, the first examiner conducted the third measurement. All subjects underwent three consecutive tests during each session. The repeatability and reproducibility of the modulation transfer function cut off frequency (MTF cutoff), the Strehl ratio, the OQAS values (OVs) at contrasts of 100%, 20% and 9%, and the objective scatter index (OSI) were analyzed. For MTF cutoff, Strehl ratio, OV100%, OV20%, OV9%, and OSI, the mean values were 39.32±9.75cpd, 0.22±0.06, 1.31±0.33, 1.33±0.39, 1.33±0.41, 0.60±0.42, respectively. Repeatability and reproducibility were good with a very low coefficient of variation and high interclass correlation coefficients (>0.88) for all parameters. Bland-Altman plots showed good correlation with 95% limits of agreement ranged from -6.04 to 6.78cpd, -0.05 to 0.05, -0.20 to 0.23, -0.29 to 0.32, -0.40 to 0.42, -0.23 to 0.21 in inter-observer, and -6.56 to 7.42cpd, -0.06 to 0.06, -0.22 to 0.24, -0.30 to 0.32, -0.35 to 0.34, -0.24 to 0.23 in inter-visit, respectively. The OQASII system yields excellent repeatability and good reproducibility for objective measurements of overall optical quality in clinic.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
ObjectType-Undefined-3
Conceived and designed the experiments: AY QW. Performed the experiments: CX TX YZ JH. Analyzed the data: AY. Wrote the paper: AY TX CX.
Competing Interests: The authors have declared that no competing interests exist.
ISSN:1932-6203
1932-6203