"Body-In-The-Loop": Optimizing Device Parameters Using Measures of Instantaneous Energetic Cost

This paper demonstrates methods for the online optimization of assistive robotic devices such as powered prostheses, orthoses and exoskeletons. Our algorithms estimate the value of a physiological objective in real-time (with a body "in-the-loop") and use this information to identify optim...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 10; no. 8; p. e0135342
Main Authors Felt, Wyatt, Selinger, Jessica C., Donelan, J. Maxwell, Remy, C. David
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 19.08.2015
Public Library of Science (PLoS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This paper demonstrates methods for the online optimization of assistive robotic devices such as powered prostheses, orthoses and exoskeletons. Our algorithms estimate the value of a physiological objective in real-time (with a body "in-the-loop") and use this information to identify optimal device parameters. To handle sensor data that are noisy and dynamically delayed, we rely on a combination of dynamic estimation and response surface identification. We evaluated three algorithms (Steady-State Cost Mapping, Instantaneous Cost Mapping, and Instantaneous Cost Gradient Search) with eight healthy human subjects. Steady-State Cost Mapping is an established technique that fits a cubic polynomial to averages of steady-state measures at different parameter settings. The optimal parameter value is determined from the polynomial fit. Using a continuous sweep over a range of parameters and taking into account measurement dynamics, Instantaneous Cost Mapping identifies a cubic polynomial more quickly. Instantaneous Cost Gradient Search uses a similar technique to iteratively approach the optimal parameter value using estimates of the local gradient. To evaluate these methods in a simple and repeatable way, we prescribed step frequency via a metronome and optimized this frequency to minimize metabolic energetic cost. This use of step frequency allows a comparison of our results to established techniques and enables others to replicate our methods. Our results show that all three methods achieve similar accuracy in estimating optimal step frequency. For all methods, the average error between the predicted minima and the subjects' preferred step frequencies was less than 1% with a standard deviation between 4% and 5%. Using Instantaneous Cost Mapping, we were able to reduce subject walking-time from over an hour to less than 10 minutes. While, for a single parameter, the Instantaneous Cost Gradient Search is not much faster than Steady-State Cost Mapping, the Instantaneous Cost Gradient Search extends favorably to multi-dimensional parameter spaces.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
Competing Interests: The authors of this manuscript have read the journal’s policy and have the following competing interests: J. Maxwell Donelan is the founder and scientific advisor to Bionic Power. This does not alter the authors’ adherence to PLOS ONE policies on sharing data and materials.
Conceived and designed the experiments: JMD WF CDR JCS. Performed the experiments: WF. Analyzed the data: WF. Contributed reagents/materials/analysis tools: JCS WF. Wrote the paper: WF CDR. Edited the manuscript: WF CDR JCS JMD. Figure design: WF CDR JCS JMD.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0135342