The Inter-Arm Diastolic Blood Pressure Difference Induced by One Arm Ischemia: A New Approach to Assess Vascular Endothelia Function

To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r) induced by one arm ischemia correlates with flow-mediated dilatation (FMD). Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D) was measured by ultrasound technique...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 9; no. 1; p. e84765
Main Authors Hu, Weitong, Li, Juxiang, Su, Hai, Wang, Jiwei, Xu, Jinsong, Liu, Yanna, Huang, Ming, Cheng, Xiaoshu
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 13.01.2014
Public Library of Science (PLoS)
Subjects
Online AccessGet full text
ISSN1932-6203
1932-6203
DOI10.1371/journal.pone.0084765

Cover

Loading…
More Information
Summary:To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r) induced by one arm ischemia correlates with flow-mediated dilatation (FMD). Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D) was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives). Following baseline diameter (D0) and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD) was calculated as the percentage increase of artery diameter (ΔD/D0). The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r). At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, P<0.05), which led to an increase of ΔDBPl-r (4.00±3.75 vs 0.78±4.47 mmHg, P<0.05). A positive correlation was seen between ΔD/D0 and ΔDBPl-r (r = 0.744, p<0.001). Furthermore, the correlation between age and ΔDBPl-r (r = -0.358, P<0.01) was similar to that between age and D/D0 (r = -0.398, P<0.01). Meanwhile, both ΔDBPl-r and ΔD/D0 were significantly lower in hypertensive patients than in normotensive patients. The inter-arm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
Conceived and designed the experiments: HS. Performed the experiments: WTH JWW JSX YNL MH. Analyzed the data: JXL. Wrote the paper: HS XSC.
Competing Interests: The authors declare no any other potential conflict of interest.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0084765