Are subject-specific musculoskeletal models robust to the uncertainties in parameter identification?

Subject-specific musculoskeletal modeling can be applied to study musculoskeletal disorders, allowing inclusion of personalized anatomy and properties. Independent of the tools used for model creation, there are unavoidable uncertainties associated with parameter identification, whose effect on mode...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 9; no. 11; p. e112625
Main Authors Valente, Giordano, Pitto, Lorenzo, Testi, Debora, Seth, Ajay, Delp, Scott L, Stagni, Rita, Viceconti, Marco, Taddei, Fulvia
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 12.11.2014
Public Library of Science (PLoS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Subject-specific musculoskeletal modeling can be applied to study musculoskeletal disorders, allowing inclusion of personalized anatomy and properties. Independent of the tools used for model creation, there are unavoidable uncertainties associated with parameter identification, whose effect on model predictions is still not fully understood. The aim of the present study was to analyze the sensitivity of subject-specific model predictions (i.e., joint angles, joint moments, muscle and joint contact forces) during walking to the uncertainties in the identification of body landmark positions, maximum muscle tension and musculotendon geometry. To this aim, we created an MRI-based musculoskeletal model of the lower limbs, defined as a 7-segment, 10-degree-of-freedom articulated linkage, actuated by 84 musculotendon units. We then performed a Monte-Carlo probabilistic analysis perturbing model parameters according to their uncertainty, and solving a typical inverse dynamics and static optimization problem using 500 models that included the different sets of perturbed variable values. Model creation and gait simulations were performed by using freely available software that we developed to standardize the process of model creation, integrate with OpenSim and create probabilistic simulations of movement. The uncertainties in input variables had a moderate effect on model predictions, as muscle and joint contact forces showed maximum standard deviation of 0.3 times body-weight and maximum range of 2.1 times body-weight. In addition, the output variables significantly correlated with few input variables (up to 7 out of 312) across the gait cycle, including the geometry definition of larger muscles and the maximum muscle tension in limited gait portions. Although we found subject-specific models not markedly sensitive to parameter identification, researchers should be aware of the model precision in relation to the intended application. In fact, force predictions could be affected by an uncertainty in the same order of magnitude of its value, although this condition has low probability to occur.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Competing Interests: Debora Testi is affiliated to the BioComputing Competence Centre, SCS s.r.l. commercial company. This does not alter the authors' adherence to PLOS ONE policies on sharing data and materials.
Conceived and designed the experiments: GV LP FT. Performed the experiments: GV LP. Analyzed the data: GV LP FT. Wrote the paper: GV. Contributed software design and development: GV LP DT AS SLD MV FT. Produced gait analysis data: RS. Edited the manuscript: GV LP DT AS SLD RS MV FT.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0112625