Patient satisfaction and penile morphology changes with postoperative penile rehabilitation 2 years after Coloplast Titan prosthesis

A common complaint after inflatable penile prosthesis surgery is reduced penile length. We previously reported how using the Coloplast Titan inflatable penile prosthesis with aggressive new length measurement technique (NLMT) coupled with postoperative IPP rehabilitation of the implant for 1-year he...

Full description

Saved in:
Bibliographic Details
Published inAsian journal of andrology Vol. 18; no. 5; pp. 754 - 758
Main Authors Pryor, Michael, Carrion, Rafael, Wang, Run, Henry, Gerard
Format Journal Article
LanguageEnglish
Published China Wolters Kluwer - Medknow Publications 01.09.2016
Medknow Publications and Media Pvt. Ltd
Medknow Publications & Media Pvt. Ltd
Medknow Publications & Media Pvt Ltd
Wolters Kluwer Medknow Publications
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A common complaint after inflatable penile prosthesis surgery is reduced penile length. We previously reported how using the Coloplast Titan inflatable penile prosthesis with aggressive new length measurement technique (NLMT) coupled with postoperative IPP rehabilitation of the implant for 1-year helped to improve patient satisfact on and erectile peni e measurements Th s is a 2 years follow-up of a prospective, three-center, study of 40 patients who underwent Titan prosthesis placement, With new length measurement technique for erectile dysfunction. Patient instructions were to inflate daily for 6 months and then inflate maximally for 1-2 h daily for 6-24 months. Fifteen penile measurements were taken before and immediately after surgery and at follow-up visits. Measurement changes were improved at 24 months as compared to immediately postoperative and at 12 months. 67.8% of subjects were satisfied with their length at 2 years, and 77% had perceived penile length that was longer (30.8%) or the same (46.2%) as prior to the surgery. 64.3% and 17.9% of subjects had increased and unchanged satisfaction, respectively, with penile length as compared to prior to penile implant surgery. All but one subject (96.5%) was satisfied with the overall function of his implant. This study suggests using the Coloplast Titan with aggressive cylinder sizing, and a postoperative penile rehabilitation inflation protocol can optimize patient satisfaction and erectile penile measurements at 2 years postimplant.
Bibliography:erectile dysfunction; penile implant surgery; penile prosthesis
A common complaint after inflatable penile prosthesis surgery is reduced penile length. We previously reported how using the Coloplast Titan inflatable penile prosthesis with aggressive new length measurement technique (NLMT) coupled with postoperative IPP rehabilitation of the implant for 1-year helped to improve patient satisfact on and erectile peni e measurements Th s is a 2 years follow-up of a prospective, three-center, study of 40 patients who underwent Titan prosthesis placement, With new length measurement technique for erectile dysfunction. Patient instructions were to inflate daily for 6 months and then inflate maximally for 1-2 h daily for 6-24 months. Fifteen penile measurements were taken before and immediately after surgery and at follow-up visits. Measurement changes were improved at 24 months as compared to immediately postoperative and at 12 months. 67.8% of subjects were satisfied with their length at 2 years, and 77% had perceived penile length that was longer (30.8%) or the same (46.2%) as prior to the surgery. 64.3% and 17.9% of subjects had increased and unchanged satisfaction, respectively, with penile length as compared to prior to penile implant surgery. All but one subject (96.5%) was satisfied with the overall function of his implant. This study suggests using the Coloplast Titan with aggressive cylinder sizing, and a postoperative penile rehabilitation inflation protocol can optimize patient satisfaction and erectile penile measurements at 2 years postimplant.
31-1795/R
SourceType-Scholarly Journals-1
content type line 14
ObjectType-Article-1
ObjectType-Feature-2
content type line 23
ISSN:1008-682X
1745-7262
1745-7262
DOI:10.4103/1008-682X.163266