Determination Method for Mono- and Diethanolamine in Workplace Air by High-performance Liquid Chromatography

[Abstract]: [Objectives]: The purpose of this research was to develop a simultaneous determination method for monoethanolamine (MEA) and diethanolamine (DEA) in workplace air for risk assessment. [Methods]: The characteristics of the proposed method, such as recovery, quantitation limit, reproducibi...

Full description

Saved in:
Bibliographic Details
Published inJournal of Occupational Health Vol. 54; no. 4; pp. 340 - 343
Main Authors Takeuchi, Akito, Kitade, Takashi, Jukurogi, Akira, Hendricks, Warren, Kaifuku, Yuichiro, Shibayama, Kenji, Natsumeda, Shuichiro, Ota, Hirokazu, Yamada, Shu, Sumino, Kimiaki, Namera, Akira, Kanno, Seiichiro
Format Journal Article
LanguageEnglish
Published Australia JAPAN SOCIETY FOR OCCUPATIONAL HEALTH 01.07.2012
John Wiley & Sons, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:[Abstract]: [Objectives]: The purpose of this research was to develop a simultaneous determination method for monoethanolamine (MEA) and diethanolamine (DEA) in workplace air for risk assessment. [Methods]: The characteristics of the proposed method, such as recovery, quantitation limit, reproducibility and storage stability of the samples, were examined. [Results]: An air sampling cassette containing two sulfuric acid-treated glass fiber filters was chosen as the sampler. The MEA and DEA were extracted from the sampler filters, derivatized with 9-fluorenylmethyloxycarbonyl chloride and then analyzed by a high-performance liquid chromatograph equipped with a fluorescence detector or photo-diode array detector. The overall recoveries from spiked samplers were 86-99 and 88-99% for MEA and DEA, respectively. The recovery after 5 days of storage in a refrigerator exceeded 95%. The overall limits of quantitation were 0.750 and 0.100 μg/sample for MEA and DEA, respectively. The relative standard deviations, which represent the overall reproducibility defined as precision, were 0.3-1.6 and 0.4-5.7% for MEA and DEA, respectively. [Conclusions]: The proposed method enables 4-h personal exposure monitoring of MEA and DEA at concentrations equaling 1/3,000-2 times the threshold limit value-time-weighted average (TLV-TWA: 3 ppm for MEA, 1 mg/m3 for DEA) adopted by the American Conference of Governmental Industrial Hygienists and also by the Japan Society for Occupational Health. The method is useful for estimating worker exposure to MEA and DEA.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1341-9145
1348-9585
1348-9585
DOI:10.1539/joh.12-0064-br