Effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography

Aim: The aim of the present study was to study the effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography (OCT). Materials and Methods: One hundred and fifty-one subjects were included from the normative study of foveal morphology carried out a...

Full description

Saved in:
Bibliographic Details
Published inIndian journal of ophthalmology Vol. 63; no. 5; pp. 427 - 431
Main Authors Parthasarathy, Mohana, Bhende, Muna
Format Journal Article
LanguageEnglish
Published India Medknow Publications 01.05.2015
Medknow Publications and Media Pvt. Ltd
Medknow Publications & Media Pvt. Ltd
Medknow Publications & Media Pvt Ltd
Wolters Kluwer Medknow Publications
Subjects
Online AccessGet full text
ISSN0301-4738
1998-3689
1998-3689
DOI10.4103/0301-4738.159877

Cover

Loading…
More Information
Summary:Aim: The aim of the present study was to study the effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography (OCT). Materials and Methods: One hundred and fifty-one subjects were included from the normative study of foveal morphology carried out at our hospital. Subjects underwent comprehensive eye examination and macular scanning using Cirrus high-definition OCT and axial length (AXL) measurement. Macular cube 512 × 128 scan protocol was used for scanning the macula. Automated measurements of the fovea namely foveal diameter, foveal slope (lateral measurements) and foveal depth (axial measurement) were taken. A correction factor for ocular magnification was done using the formula t = p × q × s, where "t0" is the corrected measurement, "p" is the magnification of OCT, "q0" is the ocular magnification, and "s" is the measurement on OCT without correction. The difference between corrected and uncorrected measurements was evaluated for statistical significance. Results: Mean AXL was 22.95 ± 0.78 mm. Refractive error ranged from −3D to +4D. Mean difference between measured and corrected foveal diameter, slope and depth was 166.05 ± 95.37 ΅m (P < 0.001), 0.81° ± 0.53° (P < 0.001) and 0.05 ± 0.49 ΅m (P = 0.178) respectively. AXL lesser than the OCT calibrated value of 24.46 mm showed an increased foveal diameter (r = 0.961, P < 0.001) and a reduced foveal slope (r = −0.863, P < 0.001) than the corrected value. Conclusion: Lateral measurements made on OCT varied with AXL s other than the OCT calibrated value of 24.46 mm. Therefore, to estimate the actual dimensions of a retinal lesion using OCT, especially lateral dimensions, we recommend correction for the ocular magnification factor.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
content type line 14
ObjectType-Feature-2
content type line 23
ISSN:0301-4738
1998-3689
1998-3689
DOI:10.4103/0301-4738.159877