Neurocysticercosis: HP10 antigen detection is useful for the follow-up of the severe patients

The most severe clinical form of neurocysticercosis (NC) occurs when cysticerci are located in the subarachnoid space at the base of the brain (SaB). The diagnosis, monitoring and treatment of NC-SaB, constitutes a severe clinical challenge. Herein we evaluate the potential of the HP10 antigen detec...

Full description

Saved in:
Bibliographic Details
Published inPLoS neglected tropical diseases Vol. 7; no. 3; p. e2096
Main Authors Fleury, Agnès, Garcia, Esperanza, Hernández, Marisela, Carrillo, Roger, Govezensky, Tzipe, Fragoso, Gladis, Sciutto, Edda, Harrison, Leslie J S, Parkhouse, R Michael Evans
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 01.03.2013
Public Library of Science (PLoS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The most severe clinical form of neurocysticercosis (NC) occurs when cysticerci are located in the subarachnoid space at the base of the brain (SaB). The diagnosis, monitoring and treatment of NC-SaB, constitutes a severe clinical challenge. Herein we evaluate the potential of the HP10 antigen detection enzyme-linked immunosorbent assay (HP10 Ag-ELISA) in the long term follow-up of NC-SaB cases. Assay performance was compared with that of Magnetic Resonance Imaging (MRI). In addition, the robustness of the HP10 Ag-ELISA was evaluated independently at two different institutions. A double-blind prospective cohort trial was conducted involving 38 NC-SaB cases and a total of 108 paired serum and cerebrospinal fluid (CSF) samples taken at intervals of 4 to 8 months for up to 43 months. At each medical visit, results of sera and CSF HP10 Ag-ELISA and MRI obtained at last visit were compared and their accuracy was evaluated retrospectively, considering radiological evolution between appointments. In the long-term follow-up study, HP10 Ag-ELISA had a better agreement than MRI with retrospective radiological evaluation. High reproducibility of HP10 Ag-ELISA between laboratories was also demonstrated. Results reported in this study establish for the first time the usefulness of the comparatively low cost HP10 Ag-ELISA for long term follow-up of NC-SaB patients.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
PMCID: PMC3591315
Conceived and designed the experiments: AF ES LJSH RMEP. Performed the experiments: EG MH RC GF. Analyzed the data: AF TG LJSH RMEP RC. Contributed reagents/materials/analysis tools: TG LJSH RMEP ES. Wrote the paper: AF EG MH RC TG GF ES LJSH RMEP.
The authors have declared that no competing interests exist.
ISSN:1935-2735
1935-2727
1935-2735
DOI:10.1371/journal.pntd.0002096