Using multiple trabecular micro-bypass stents in cataract patients to treat open-angle glaucoma

Purpose To evaluate the efficacy of multiple trabecular micro-bypass stents combined with cataract surgery in patients with open-angle glaucoma (OAG) and cataract. Setting Private practice, Mississauga, Ontario, Canada. Design Comparative case series. Methods Eyes with OAG had implantation of 2 or 3...

Full description

Saved in:
Bibliographic Details
Published inJournal of cataract and refractive surgery Vol. 38; no. 11; pp. 1911 - 1917
Main Authors Belovay, Graham W., MD, Naqi, Abdulla, MD, Chan, Brian J., MD, Rateb, Mahmoud, MD, Ahmed, Iqbal Ike K., MD
Format Journal Article
LanguageEnglish
Published New York, NY Elsevier Inc 01.11.2012
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose To evaluate the efficacy of multiple trabecular micro-bypass stents combined with cataract surgery in patients with open-angle glaucoma (OAG) and cataract. Setting Private practice, Mississauga, Ontario, Canada. Design Comparative case series. Methods Eyes with OAG had implantation of 2 or 3 micro-bypass stents with concurrent cataract surgery and follow-up through 1 year. Efficacy measures were intraocular pressure (IOP) and topical ocular hypotensive medication use. Safety assessment included complications and corrected distance visual acuity (CDVA). Results The study comprised 53 eyes (47 patients); 28 had implantation of 2 stents and 25 had implantation of 3 stents. The overall mean 1-year postoperative IOP was 14.3 mm Hg, which was significantly lower than preoperative IOP overall and in each group ( P <.001). The target IOP was achieved in a significantly higher proportion of eyes at 1 year versus preoperatively (77% versus 43%; P <.001). Overall, 83% of eyes had a decrease in topical ocular hypotensive medication at 1 year from preoperatively, with a 74% decrease in the mean number of medications (from 2.7 to 0.7) at 1 year ( P <.001). The 3-stent group was on significantly fewer medications than the 2-stent group at 1 year (0.4 versus 1.0; P =.04). Conclusions Using multiple micro-bypass stents with concurrent cataract surgery led to a mean postoperative IOP of less than 15 mm Hg and allowed patients to achieve target pressure control with significantly fewer medications through 1 year. Financial Disclosure Dr. Ahmed is a consultant to Glaukos Corp. No other author has a financial or proprietary interest in any material or method mentioned.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0886-3350
1873-4502
DOI:10.1016/j.jcrs.2012.07.017