Endurance-oriented training program with children and adolescents on maintenance hemodialysis to enhance dialysis efficacy—DiaSport
Objective Pediatric patients spend significant time on maintenance hemodialysis (HD) and traveling. They are often not capable of participating in sports activities. To assess the effects of exercise training during HD on dialysis efficacy in children and adolescents, we set up a multi-center random...
Saved in:
Published in | Pediatric nephrology (Berlin, West) Vol. 36; no. 12; pp. 3923 - 3932 |
---|---|
Main Authors | , , , , , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Berlin/Heidelberg
Springer Berlin Heidelberg
01.12.2021
Springer Springer Nature B.V |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Objective
Pediatric patients spend significant time on maintenance hemodialysis (HD) and traveling. They are often not capable of participating in sports activities. To assess the effects of exercise training during HD on dialysis efficacy in children and adolescents, we set up a multi-center randomized controlled trial (RCT).
Methods
Patients on HD, age 6 to 18 years, were randomized either to 3× weekly bicycle ergometer training or to no training during HD for 12 weeks. Change in single-pool Kt/V (spKt/V) was the primary outcome parameter.
Results
We randomized 54 patients of whom 45 qualified (23 in the intervention and 22 in the waiting control group, 14.5 ± 3.01 years, 32 male and 13 female) for the intention-to-treat (ITT) population. Only 26 patients finished study per-protocol (PP). Training was performed for an average of 11.96 weeks (0.14–13.14) at 2.08 ± 0.76 times per week and for a weekly mean of 55.52 ± 27.26 min. Single-pool Kt/V was similar in the intervention compared to the control group (1.70 [0.33] vs. 1.79 [0.55]) at V0 and (1.70 [0.36] vs. 1.71 [0.51]) at V1; secondary endpoints also showed no difference in both ITT and PP analysis. No significant adverse events were reported. No bleeding or needle dislocation occurred in 1670 training sessions.
Conclusions
Intradialytic bicycle training is safe, but does not improve dialysis efficacy and physical fitness. However, the study can be considered underpowered, particularly because of high dropout rates. Future studies need better strategies to increase motivation and compliance and other more effective/intensive exercise measures should be evaluated.
Trial registration
The trial was registered in
ClinicalTrials.Gov
(
Clinicaltrials.gov
identifier: NCT01561118) on March 22, 2012. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 ObjectType-News-3 content type line 23 |
ISSN: | 0931-041X 1432-198X |
DOI: | 10.1007/s00467-021-05114-8 |