Twenty-Four-Hour Contact Lens Sensor Monitoring of Aqueous Humor Dynamics in Surgically or Medically Treated Glaucoma Patients

Aim. This study assessed the 24 h circadian rhythm of intraocular pressure (IOP) using a contact lens sensor in three groups of patients with open-angle glaucoma. Methods. This study was a monocentric, cross-sectional, nonrandomized, prospective, pilot study. Eighty-nine patients were enrolled: 29 p...

Full description

Saved in:
Bibliographic Details
Published inJournal of ophthalmology Vol. 2019; no. 2019; pp. 1 - 10
Main Authors Figus, Michele, Casini, Giamberto, Loiudice, Pasquale, Passani, Andrea, Toro, Mario, Ferreras, Antonio L., Ortenzio, Pierluigi, Posarelli, Chiara, Oddone, Francesco
Format Journal Article
LanguageEnglish
Published Cairo, Egypt Hindawi Publishing Corporation 01.01.2019
Hindawi
John Wiley & Sons, Inc
Hindawi Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Aim. This study assessed the 24 h circadian rhythm of intraocular pressure (IOP) using a contact lens sensor in three groups of patients with open-angle glaucoma. Methods. This study was a monocentric, cross-sectional, nonrandomized, prospective, pilot study. Eighty-nine patients were enrolled: 29 patients previously underwent an Ex-PRESS mini glaucoma device procedure (Group 1), 28 patients previously underwent Hydrus microstent implantation (Group 2), and 32 patients were currently being treated medically for primary open-angle glaucoma (Group 3). Circadian rhythm patterns were considered with five circadian indicators: fluctuation ranges, maximum, minimum, acrophase (time of peak value), and bathyphase (time of trough value). A two-tailed Mann–Whitney U-test was used to evaluate differences between groups. Results. All subjects exhibited a circadian rhythm and a nocturnal pattern. The signal fluctuation range was significantly smaller in the surgical groups than in the medically treated group (Group 1 vs. Group 3, p=0.003; Group 2 vs. Group 3, p=0.010). Subjects who underwent the Ex-PRESS procedure (Group 1) exhibited significant differences compared with the drug therapy group (Group 3) with regard to the minimum value (p=0.015), acrophase (p=0.009), and bathyphase (p=0.002). The other circadian indicators were not significantly different among groups. Conclusions. Patients who underwent IOP-lowering surgery had an intrinsic nyctohemeral rhythm. Both surgical procedures, Ex-PRESS and Hydrus, were associated with smaller signal fluctuations compared with medical treatment.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Academic Editor: Maurizio Uva
ISSN:2090-004X
2090-0058
DOI:10.1155/2019/9890831