Ultra-low-dose CT for extremities in an acute setting: initial experience with 203 subjects

Objective The purpose of this study was to assess if ultra-low-dose CT is a useful clinical alternative to digital radiographs in the evaluation of acute wrist and ankle fractures. Materials and methods An ultra-low-dose protocol was designed on a 256-slice multi-detector CT. Patients from the emerg...

Full description

Saved in:
Bibliographic Details
Published inSkeletal radiology Vol. 49; no. 4; pp. 531 - 539
Main Authors Alagic, Zlatan, Bujila, Robert, Enocson, Anders, Srivastava, Subhash, Koskinen, Seppo K.
Format Journal Article
LanguageEnglish
Published Berlin/Heidelberg Springer Berlin Heidelberg 01.04.2020
Springer
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective The purpose of this study was to assess if ultra-low-dose CT is a useful clinical alternative to digital radiographs in the evaluation of acute wrist and ankle fractures. Materials and methods An ultra-low-dose protocol was designed on a 256-slice multi-detector CT. Patients from the emergency department were evaluated prospectively. After initial digital radiographs, an ultra-low-dose CT was performed. Two readers independently analyzed the images. Also, the radiation dose, examination time, and time to preliminary report was compared between digital radiographs and CT. Results In 207 extremities, digital radiography and ultra-low-dose CT detected 73 and 109 fractures, respectively ( p  < 0.001). The odds ratio for fracture detection with ultra-low-dose CT vs. digital radiography was 2.0 (95% CI, 1.4–3.0). CT detected additional fracture-related findings in 33 cases (15.9%) and confirmed or ruled out suspected fractures in 19 cases (9.2%). The mean effective dose was comparable between ultra-low-dose CT and digital radiography (0.59 ± 0.33 μSv, 95% CI 0.47–0.59 vs. 0.53 ± 0.43 μSv, 95% CI 0.54–0.64). The mean combined examination time plus time to preliminary report was shorter for ultra-low-dose CT compared to digital radiography (7.6 ± 2.5 min, 95% CI 7.1–8.1 vs. 9.8 ± 4.7 min, 95% CI 8.8–10.7) ( p  = 0.002). The recommended treatment changed in 34 (16.4%) extremities. Conclusions Ultra-low-dose CT is a useful alternative to digital radiography for imaging the peripheral skeleton in the acute setting as it detects significantly more fractures and provides additional clinically important information, at a comparable radiation dose. It also provides faster combined examination and reporting times.
ISSN:0364-2348
1432-2161
1432-2161
DOI:10.1007/s00256-019-03309-7