Clinical diagnostic value of simultaneous amplification and testing for the diagnosis of sputum-scarce pulmonary tuberculosis

Since 20% of pulmonary tuberculosis (PTB) patients are asymptomatic, the early detection of PTB is a challenge particularly in sputum-scarce patients and diagnostic accuracy based solely on clinical characteristics and chest X-ray/CT scans are not always satisfactory. The AmpSure simultaneous amplif...

Full description

Saved in:
Bibliographic Details
Published inBMC infectious diseases Vol. 17; no. 1; p. 545
Main Authors Yan, Liping, Zhang, Qing, Xiao, Heping
Format Journal Article
LanguageEnglish
Published England BioMed Central Ltd 05.08.2017
BioMed Central
BMC
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Since 20% of pulmonary tuberculosis (PTB) patients are asymptomatic, the early detection of PTB is a challenge particularly in sputum-scarce patients and diagnostic accuracy based solely on clinical characteristics and chest X-ray/CT scans are not always satisfactory. The AmpSure simultaneous amplification and testing method for the detection of Mycobacterium tuberculosis (SAT-TB assay) is an alternative approach to diagnose PTB. In the present study, we analyzed the usefulness of the SAT-TB assay for PTB diagnosis in sputum-scarce patients. A total of 840 patients were prospectively enrolled for PTB diagnosis with bronchial alveolar lavage fluid (BALF) used as the samples for the SAT-TB assay. Of these, 536 had a definite diagnosis of PTB confirmed by positive microbiology culture, or clinical diagnosis of active PTB following anti-TB treatment with a favorable response. The SAT-TB assay showed a 76.44% agreement with the culture test. The sensitivity and specificity of the SAT-TB assay were 50.75% and 94.73%, respectively. The sensitivity of SAT-TB was significantly higher than that of BALF cultures (21.64%) (X  = 49.1503; P < 0.001) and smears (4.48%) (X  = 175.2315; P < 0.001). The specificity of SAT-TB was slightly lower than that of BALF cultures (98.25%) (X  = 2.0727; P = 0.150) and smears (98.25%) (X  = 2.0727; P = 0.150). The accuracy rates were 63.87% for SAT-TB, 44.50% for BALF cultures and 29.84% for BALF smears. The high accuracy of the SAT-TB assay indicated that active PTB is present and anti-TB treatment is strongly recommended regardless of smear and culture test results for sputum scarce active PTB suspected patients when BALF SAT-TB is positive.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1471-2334
1471-2334
DOI:10.1186/s12879-017-2647-7