Clinical diagnostic value of simultaneous amplification and testing for the diagnosis of sputum-scarce pulmonary tuberculosis
Since 20% of pulmonary tuberculosis (PTB) patients are asymptomatic, the early detection of PTB is a challenge particularly in sputum-scarce patients and diagnostic accuracy based solely on clinical characteristics and chest X-ray/CT scans are not always satisfactory. The AmpSure simultaneous amplif...
Saved in:
Published in | BMC infectious diseases Vol. 17; no. 1; p. 545 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
England
BioMed Central Ltd
05.08.2017
BioMed Central BMC |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Since 20% of pulmonary tuberculosis (PTB) patients are asymptomatic, the early detection of PTB is a challenge particularly in sputum-scarce patients and diagnostic accuracy based solely on clinical characteristics and chest X-ray/CT scans are not always satisfactory. The AmpSure simultaneous amplification and testing method for the detection of Mycobacterium tuberculosis (SAT-TB assay) is an alternative approach to diagnose PTB. In the present study, we analyzed the usefulness of the SAT-TB assay for PTB diagnosis in sputum-scarce patients.
A total of 840 patients were prospectively enrolled for PTB diagnosis with bronchial alveolar lavage fluid (BALF) used as the samples for the SAT-TB assay. Of these, 536 had a definite diagnosis of PTB confirmed by positive microbiology culture, or clinical diagnosis of active PTB following anti-TB treatment with a favorable response.
The SAT-TB assay showed a 76.44% agreement with the culture test. The sensitivity and specificity of the SAT-TB assay were 50.75% and 94.73%, respectively. The sensitivity of SAT-TB was significantly higher than that of BALF cultures (21.64%) (X
= 49.1503; P < 0.001) and smears (4.48%) (X
= 175.2315; P < 0.001). The specificity of SAT-TB was slightly lower than that of BALF cultures (98.25%) (X
= 2.0727; P = 0.150) and smears (98.25%) (X
= 2.0727; P = 0.150). The accuracy rates were 63.87% for SAT-TB, 44.50% for BALF cultures and 29.84% for BALF smears.
The high accuracy of the SAT-TB assay indicated that active PTB is present and anti-TB treatment is strongly recommended regardless of smear and culture test results for sputum scarce active PTB suspected patients when BALF SAT-TB is positive. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1471-2334 1471-2334 |
DOI: | 10.1186/s12879-017-2647-7 |