A fixed-target platform for serial femtosecond crystallography in a hydrated environment

For serial femtosecond crystallography at X-ray free-electron lasers, which entails collection of single-pulse diffraction patterns from a constantly refreshed supply of microcrystalline sample, delivery of the sample into the X-ray beam path while maintaining low background remains a technical chal...

Full description

Saved in:
Bibliographic Details
Published inIUCrJ Vol. 7; no. Pt 1; pp. 30 - 41
Main Authors Shelby, M L, Gilbile, D, Grant, T D, Seuring, C, Segelke, B W, He, W, Evans, A C, Pakendorf, T, Fischer, P, Hunter, M S, Batyuk, A, Barthelmess, M, Meents, A, Coleman, M A, Kuhl, T L, Frank, M
Format Journal Article
LanguageEnglish
Published England International Union of Crystallography 01.01.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:For serial femtosecond crystallography at X-ray free-electron lasers, which entails collection of single-pulse diffraction patterns from a constantly refreshed supply of microcrystalline sample, delivery of the sample into the X-ray beam path while maintaining low background remains a technical challenge for some experiments, especially where this methodology is applied to relatively low-ordered samples or those difficult to purify and crystallize in large quantities. This work demonstrates a scheme to encapsulate biological samples using polymer thin films and graphene to maintain sample hydration in vacuum conditions. The encapsulated sample is delivered into the X-ray beam on fixed targets for rapid scanning using the Roadrunner fixed-target system towards a long-term goal of low-background measurements on weakly diffracting samples. As a proof of principle, we used microcrystals of the 24 kDa rapid encystment protein (REP24) to provide a benchmark for polymer/graphene sandwich performance. The REP24 microcrystal unit cell obtained from our sandwiched in-vacuum sample was consistent with previously established unit-cell parameters and with those measured by us without encapsulation in humidified helium, indicating that the platform is robust against evaporative losses. While significant scattering from water was observed because of the sample-deposition method, the polymer/graphene sandwich itself was shown to contribute minimally to background scattering.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
USDOE Office of Science (SC), Basic Energy Sciences (BES) (SC-22)
National Institutes of Health (NIH)
AC52-07NA27344; AC02-76SF00515; 1R01GM117342-01; STC-1231306
USDOE National Nuclear Security Administration (NNSA)
LLNL-JRNL-773953
These authors contributed equally.
ISSN:2052-2525
2052-2525
DOI:10.1107/s2052252519014003