Angioscopic Assessments at 3 Months After Fluoropolymer-Based Paclitaxel-Eluting Stent Implantation for Femoropopliteal Endovascular Intervention

Background:The detailed mechanism of early-phase arterial healing after novel fluoropolymer-based paclitaxel-eluting stent (PES) implantation in the femoropopliteal (FP) lesions has not been elucidated.Methods and Results:We evaluated the intravascular status of 20 PES implanted in 11 FP lesions of...

Full description

Saved in:
Bibliographic Details
Published inCirculation Journal Vol. 84; no. 11; pp. 1999 - 2005
Main Authors Tsujimura, Takuya, Ishihara, Takayuki, Iida, Osamu, Hata, Yosuke, Kurata, Naoya, Asai, Mitsutoshi, Masuda, Masaharu, Okamoto, Shin, Nanto, Kiyonori, Kanda, Takashi, Matsuda, Yasuhiro, Mano, Toshiaki
Format Journal Article
LanguageEnglish
Published Japan The Japanese Circulation Society 23.10.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background:The detailed mechanism of early-phase arterial healing after novel fluoropolymer-based paclitaxel-eluting stent (PES) implantation in the femoropopliteal (FP) lesions has not been elucidated.Methods and Results:We evaluated the intravascular status of 20 PES implanted in 11 FP lesions of 9 patients using angioscopy at approximately 3 months after implantation. Angioscopic images were analyzed to determine (1) the dominant degree of neointimal coverage (NIC) over the stent; (2) the extent of uncovered struts; and (3) the presence of intrastent thrombus. NIC was classified into 4 grades: grade 0, stent struts fully visible; grade 1, stent struts bulging into the lumen although covered; grade 2, stent struts embedded in neointima, but translucently visible; grade 3, stent struts fully embedded and invisible. The extent of uncovered struts was scored as follows: score 0, no uncovered struts of the entire stent; score 1, uncovered struts area approximately <30% of the stent; and score 2, uncovered struts area approximately ≥30% of the stent. In total, 90% of stents demonstrated grade 1 dominant NIC and 10% showed grade 2 dominant NIC; 85% of stents showed an uncovered stent score of 0, and the remainder had a score of 1. Thrombus was observed in all stents.Conclusions:Widely uncovered stent struts were not observed by angioscopy at 3 months after PES implantation in these FP lesions, even with the detection of thrombus adhesion.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1346-9843
1347-4820
1347-4820
DOI:10.1253/circj.CJ-20-0551