Comparative evaluation of shear bond strength between titanium-ceramic and cobalt-chromium-ceramic: An in vitro study

Aim: The aim of this study was to evaluate and compare the shear bond strength between ceramic layered over titanium and ceramic layered over cobalt-chromium alloy, which are used in the fabrication of screw-retained implant prosthesis. Settings and Design: In-vitro - Comparative study. Materials an...

Full description

Saved in:
Bibliographic Details
Published inThe journal of Indian Prosthodontic Society Vol. 21; no. 3; pp. 276 - 280
Main Authors Vaska, Kamal, Nakka, Chandrasekhar, Reddy, K, Chintalapudi, Siddesh
Format Journal Article
LanguageEnglish
Published New Delhi Wolters Kluwer India Pvt. Ltd 01.07.2021
Medknow Publications and Media Pvt. Ltd
Medknow Publications & Media Pvt. Ltd
Wolters Kluwer - Medknow
Wolters Kluwer Medknow Publications
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Aim: The aim of this study was to evaluate and compare the shear bond strength between ceramic layered over titanium and ceramic layered over cobalt-chromium alloy, which are used in the fabrication of screw-retained implant prosthesis. Settings and Design: In-vitro - Comparative study. Materials and Method: A total of 40 samples (20 samples of Titanium in Group 1 and 20 samples of Cobalt-Chromium in Group 2) were fabricated. For all the samples bonding agent was applied on to the sand blasted surface and firing was done at a temperature of 980° C. A layer of opaque was applied using a brush and placed back in the furnace at a temperature of 910° C. Then ceramic was layered on to the surface with putty index as guide and firing was done in the ceramic furnace up to a temperature of 880° C followed by glazing. Shear bond strength was measured using a Universal Testing Machine. Statistical Analyses Used: One sample t-test and paired sample t-test. Results: Descriptive statistics were done to calculate mean differences between groups and samples. The mean bond strength of titanium- ceramic samples was more than those of cobalt-chromium-ceramic samples. Inferential statistics used in the study were one sample t-test for intra-group comparison and paired sample t-test for inter group comparison which showed no statistically significant difference between the two metal types (P value = 0.163). Conclusion: The shear bond strength of ceramic veneered over titanium meets the ISO requirements of minimum shear bond strength between metal-ceramic systems and has achieved the clinically acceptable values. The use of titanium super structure over titanium implants reduces the adverse effects and avoids undesirable effects.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0972-4052
1998-4057
DOI:10.4103/jips.jips_81_21