Validation of the diagnostic criteria for IgG4-related kidney disease (IgG4-RKD) 2011, and proposal of a new 2020 version
Background In 2011, the IgG4-related kidney disease (IgG4-RKD) working group of the Japanese Society of Nephrology proposed diagnostic criteria for IgG4-RKD. The aim of the present study was to validate those criteria and develop a revised version. Methods Between April 2012 and May 2019, we retrosp...
Saved in:
Published in | Clinical and experimental nephrology Vol. 25; no. 2; pp. 99 - 109 |
---|---|
Main Authors | , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Singapore
Springer Singapore
01.02.2021
Springer Nature B.V |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Background
In 2011, the IgG4-related kidney disease (IgG4-RKD) working group of the Japanese Society of Nephrology proposed diagnostic criteria for IgG4-RKD. The aim of the present study was to validate those criteria and develop a revised version.
Methods
Between April 2012 and May 2019, we retrospectively collected Japanese patients with kidney disease, for whom data on serum IgG4 values and/or immunohistological staining for IgG4 in renal biopsy samples were available. These patients were classified as IgG4-RKD or non-IgG4-RKD based on the diagnostic criteria for IgG4-RKD 2011, and the results were evaluated by expert opinion. Accordingly, we developed some revised versions of the criteria, and the version showing the best performance in the present cohort was proposed as the IgG4-RKD criteria for 2020.
Results
Of 105 included patients, the expert panel diagnosed 55 as having true IgG4-RKD and 50 as mimickers. The diagnostic criteria for IgG4-RKD 2011 had a sensitivity of 72.7% and a specificity of 90.0% in this cohort. Of the 15 patients with true IgG4-RKD who were classified as non-IgG4-RKD, all lacked biopsy-proven extra-renal lesions, although many had clinical findings highly suggestive of IgG4-RD. The revised version to which “bilateral lacrimal, submandibular or parotid swelling, imaging findings compatible with type 1 autoimmune pancreatitis or retroperitoneal fibrosis” was added as an item pertaining to extra-renal organ(s) improved the sensitivity to 90.9% while the specificity remained at 90.0%.
Conclusion
The revised version has considerably improved test performance after addition of the new extra-renal organ item (imaging and clinical findings). |
---|---|
ISSN: | 1342-1751 1437-7799 |
DOI: | 10.1007/s10157-020-01993-7 |