Performance Assessment of Xpert MTB/RIF Assay for Detecting Pulmonary Tuberculosis and Rifampin Resistance in a Tertiary Care Hospital in Korea

In this study, we aimed to assess the performance of the Xpert MTB/RIF assay for the detection of pulmonary tuberculosis compared to the acid-fast bacilli (AFB) smear and culture analysis, and the incidence of rifampin resistance using the drug susceptibility test. The specimens referred for AFB sme...

Full description

Saved in:
Bibliographic Details
Published inJapanese Journal of Infectious Diseases Vol. 74; no. 6; pp. 537 - 542
Main Authors Chang, Jeonghyun, Sung, Heungsup, Jo, Kyung-Wook, Shim, Tae Sun, Kim, Mi-Na
Format Journal Article
LanguageEnglish
Published Japan National Institute of Infectious Diseases, Japanese Journal of Infectious Diseases Editorial Committee 22.11.2021
Japan Science and Technology Agency
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this study, we aimed to assess the performance of the Xpert MTB/RIF assay for the detection of pulmonary tuberculosis compared to the acid-fast bacilli (AFB) smear and culture analysis, and the incidence of rifampin resistance using the drug susceptibility test. The specimens referred for AFB smear and culture analysis and Xpert MTB/RIF assay from April 2015 to March 2018 were retrospectively reviewed. The sensitivity, specificity, and mean cycle threshold (Ct) values obtained in Xpert MTB/RIF assay and for rifampin resistance were analyzed. The results of Xpert MTB/RIF assay for pulmonary tuberculosis were evaluated based on the AFB smear grade. Among 3,840 specimens, 491 were positive in Xpert MTB/RIF assay and 626 in culture analysis. The sensitivity and specificity of Xpert MTB/RIF assay were 75.6% and 99.4%, respectively. The sensitivity of Xpert MTB/RIF assay for smear-positive/culture-positive specimens was 98.6% and that of smear-negative and -trace/culture-positive specimens was 63.1%. The positivity of Xpert MTB/RIF assay for culture-positive specimens was 89.9%, 98.6%, 95.7%, 100.0%, and 100.0% for the smear grades trace, 1+, 2+, 3+, 4+, respectively. The Ct values of 491 specimens significantly decreased as the AFB smear grade increased (P < 0.0001). The Ct values of smear-positive, -trace, and -negative specimens were 21.7 ± 4.2, 26.5 ± 3.9, and 27.4 ± 3.6, respectively. Rifampin resistance evaluated using Xpert MTB/RIF assay and culture analysis exhibited a correlation of 98.3%. The region covered by probe E was the most frequently mutated region (50.0%). Xpert MTB/RIF assay demonstrated reliable performance in detecting pulmonary tuberculosis from smear-positive and culture-positive specimens; however, further improvements are still required to detect smear-negative and culture-positive specimens.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1344-6304
1884-2836
DOI:10.7883/yoken.JJID.2020.978