Inappropriate Use of D-Values for Determining Biocidal Activity of Various Antimicrobials

:  The objective of this study was to investigate the application of established D‐value calculations to survival curves for various bacteria using the following antimicrobials: acidified sodium chlorite, triclosan, octanoic acid, and sodium hydroxide. D‐values can be calculated in 3 ways, a linear...

Full description

Saved in:
Bibliographic Details
Published inJournal of food science Vol. 76; no. 1; pp. M8 - M11
Main Authors Hines, Jesse D., McKelvey, Pamela J., Bodnaruk, Peter W.
Format Journal Article
LanguageEnglish
Published Malden, USA Blackwell Publishing Inc 01.01.2011
Wiley
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary::  The objective of this study was to investigate the application of established D‐value calculations to survival curves for various bacteria using the following antimicrobials: acidified sodium chlorite, triclosan, octanoic acid, and sodium hydroxide. D‐values can be calculated in 3 ways, a linear regression, an endpoint calculation, or an average of multiple endpoint calculations. The assumption made in calculating a D‐value is that the rate of kill follows 1st‐order kinetics under specified treatment conditions. Each antimicrobial solution was challenged with approximately 108 CFU/mL of Staphylococcus aureus, Listeria monocytogenes, Salmonella enterica subsp. enterica, and Escherichia coli independently and in triplicate. Test systems were sampled at each of the 10 time points over a period of 7 min, neutralized, pour plated then incubated at 35 °C for 48 h (AOAC official method 960.09). Survival curves using the log‐transformed data were calculated using regression analysis. Correlations coefficients for all linear regression analyses ranged between 0.291 and 0.982, with 6 of the 16 different treatment systems having an R2 value below 0.7. Methods used for calculating D‐values should lead to the same result if the survival curve in a given condition is linear. The calculated D‐values were different using endpoint analysis (Stumbo method), linear regression, and average of multiple endpoints. This study demonstrates the nonlinearity of inactivation curves of antimicrobials. D‐value estimations cannot be reliably used to illustrate biocidal activity in antimicrobial test systems.
Bibliography:ArticleID:JFDS1923
ark:/67375/WNG-0LMC6DB1-M
istex:E43052B74493CF7319BB530CFF2C530C6A8F0C58
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:0022-1147
1750-3841
DOI:10.1111/j.1750-3841.2010.01923.x