Heavy metal in radiology: how to reliably differentiate between lodged copper and lead bullets using CT numbers
Background The in situ classification of bullets is of interest in forensic investigations when the bullet cannot be removed. Although computed tomography (CT) is usually performed on shooting victims, visual assessment, or caliber measurements using CT can be challenging or infeasible if the bullet...
Saved in:
Published in | European radiology experimental Vol. 4; no. 1; p. 43 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
Cham
Springer International Publishing
06.07.2020
Springer Nature B.V SpringerOpen |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Background
The
in situ
classification of bullets is of interest in forensic investigations when the bullet cannot be removed. Although computed tomography (CT) is usually performed on shooting victims, visual assessment, or caliber measurements using CT can be challenging or infeasible if the bullets are deformed or fragmented. Independent from the bullet’s intactness, x-ray attenuation values (CT numbers) may provide information regarding the material of the bullet.
Methods
Ethical approval was not required (animal cadavers) or waived by the ethics committee (decedents). Copper and lead bullets were fired into animal cadavers, which then underwent CT scanning at four energy levels (80, 100, 120, and 140 kVp). CT numbers were measured within regions of interest (ROIs). In addition to comparing CT numbers, the dual-energy index (DEI), representing the ratio between the CT numbers of two energy levels, was calculated. The most appropriate method was applied for decedents with fatal gunshot wounds.
Results
CT numbers demonstrated no significant difference between copper and lead bullets, and false classifications can easily occur. DEI calculations revealed significant differences between the two groups of bullets. The 120/140 DEIs calculated from the maximum CT numbers obtained from ROIs at the edge of copper
versus
lead bullets presented a significant difference (
p
= 0.002) and a gap between the CT numbers of copper and lead bullets and was successfully applied for the decedents.
Conclusions
This study presents a viable method for distinguishing copper and lead bullets
in situ
via CT and highlights the potential pitfalls of incorrect classifications. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 2509-9280 2509-9280 |
DOI: | 10.1186/s41747-020-00168-z |