Multiplexed immunobead-based assay for detection of oral cancer protein biomarkers in saliva

Objective:  For clinical applications of biomarkers, there is a need for multiplex assays using high throughput platforms. The objective of this study was to determine the efficacy of Luminex Multianalyte Profiling (xMAP) technology for measurement of salivary proteins and to evaluate whether multip...

Full description

Saved in:
Bibliographic Details
Published inOral diseases Vol. 14; no. 8; pp. 705 - 712
Main Authors Arellano-Garcia, ME, Hu, S, Wang, J, Henson, B, Zhou, H, Chia, D, Wong, DT
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Publishing Ltd 01.11.2008
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective:  For clinical applications of biomarkers, there is a need for multiplex assays using high throughput platforms. The objective of this study was to determine the efficacy of Luminex Multianalyte Profiling (xMAP) technology for measurement of salivary proteins and to evaluate whether multiplex assays are as effective as single‐plex assays and enzyme‐linked immunosorbent assay (ELISA). Results:  The average levels of interleukin‐8 (IL‐8) from the single‐plex assay were 3313.2 ± 3759.8 pg ml−1 [oral squamous cell carcinoma (OSCC), n = 20] and 1061.7 ± 1978.8 pg ml−1 (control, n = 20). The IL‐1β average levels from the single‐plex assay were 945.2 ± 1134.8 pg ml−1 (OSCC, n = 20) and 314.2 ± 444.8 pg ml−1 (control, n = 20). The average levels of IL‐8 from the multiplex assay were 2834.9 ± 3385.6 pg ml−1 (OSCC, n = 20) and 947.3 ± 2036.8 pg ml−1 (control, n = 20). The IL‐1β average levels from the multiplex assay were 1013.5 ± 1221.1 pg ml−1 (OSCC, n = 20) and 376.3 ± 576.3 pg ml−1 (control, n = 20). The correlation coefficient between Luminex and ELISA assay for IL‐8 (n = 19) and IL‐1β (n = 19) was 0.91 and 0.84, respectively. Conclusion:  Luminex xMAP single‐plex and multiplex assays are as effective as ELISA assays for quantification of proteins in saliva. Both IL‐8 and IL‐1β were expressed at significantly higher levels in OSCC subjects than in the matched healthy control subjects.
Bibliography:ArticleID:ODI1488
ark:/67375/WNG-GB7C8X3M-6
istex:17EDFAFDDFA38F3BCAC8EAE14AC216B86DB530B6
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
Martha E. Arellano-Garcia contributed to the designing of the experiment, acquisition, analysis and interpretation of the data. She also drafted the paper. She Hu provided his expertise and designed the experiment. He had a major contribution in the analysis and interpretation of data. He also helped draft the paper and critically revised it. Hui Zhou is the statistician who analysed the data and made statistical calculation. Jianghua Wang is the clinician who collected the patient samples and obtained written consent. Bradely Henson is the clinician who helped collect the patient samples. David Chia provided his expertise and knowledge about multiplexing technology and provided the instrument for data acquisition. David T. Wong provided expertise in designing the study and critically revised the manuscript.
Author contributions
ISSN:1354-523X
1601-0825
1601-0825
DOI:10.1111/j.1601-0825.2008.01488.x