Fingerprint Spectrophotometric Methods for the Determination of Co-Formulated Otic Solution of Ciprofloxacin and Fluocinolone Acetonide in Their Challengeable Ratio
Six spectrophotometric methods were developed to determine a new single-dose otic solution known as “Otovel®,” which consists of two components: the major one is ciprofloxacin (CIP) and the minor is fluocinolone acetonide (FLU). The ratio of (CIP) and (FLU) in Otovel® is 12 : 1, which is considered...
Saved in:
Published in | Journal of analytical methods in chemistry Vol. 2019; no. 2019; pp. 1 - 14 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
Cairo, Egypt
Hindawi Publishing Corporation
2019
Hindawi John Wiley & Sons, Inc Hindawi Limited |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Six spectrophotometric methods were developed to determine a new single-dose otic solution known as “Otovel®,” which consists of two components: the major one is ciprofloxacin (CIP) and the minor is fluocinolone acetonide (FLU). The ratio of (CIP) and (FLU) in Otovel® is 12 : 1, which is considered a challengeable ratio for UV determination. Thus, spectrum addition as a sample enrichment technique was required for the analysis of (FLU) low concentration. All these methods were capable of resolving the spectra for each component in D0 belonging to the fingerprint resolution technique. The former absorptivity centering (a-centering) method was recently developed in 2018; it was effectively applied for its solution of both binary components in Otovel®, while another method, ratio subtraction (RS), is considered as an original resolution method that could be applied to determine only one component in mixtures. However, the other four methods that are related to their original method (RS) were extended ratio subtraction (EXRS), constant multiplication (CM), unified constant subtraction (UCS), and spectrum subtraction (SS). They were also easily applied for completing the quantification of binary mixture drugs present in Otovel®. The linearity ranges were found to be 3.0–15.0 μg/mL for (CIP) and (FLU), respectively. All results acquired from the proposed methods were successfully estimated according to ICH criteria and were statistically compared with official ones where no differences were noticed. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 Academic Editor: Antonio V. Herrera-Herrera |
ISSN: | 2090-8865 2090-8873 |
DOI: | 10.1155/2019/8919345 |