Personalization of injection protocols to the individual patient's blood volume and automated tube voltage selection (ATVS) in coronary CTA

The aim was to assess personalised contrast media (CM) protocols-based on patient's blood volume (BV) and automated tube voltage selection (ATVS)-in coronary computed tomography angiography (CCTA). A total of 114 consecutive patients received an ECG-triggered or ECG-gated helical scan on a 3rd-...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 13; no. 9; p. e0203682
Main Authors Eijsvoogel, Nienke G, Hendriks, Babs M F, Willigers, Jef L, Martens, Bibi, Carati, Luc F, Horehledova, Barbora, Kietselaer, Bastiaan L J H, Crijns, Harry J G M, Wildberger, Joachim E, Das, Marco
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 26.09.2018
Public Library of Science (PLoS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The aim was to assess personalised contrast media (CM) protocols-based on patient's blood volume (BV) and automated tube voltage selection (ATVS)-in coronary computed tomography angiography (CCTA). A total of 114 consecutive patients received an ECG-triggered or ECG-gated helical scan on a 3rd-generation dual-source CT with 70-120kV (ATVS) and 330mAsqual.ref. CM was adapted to BV, scan time (s) and kV. Image quality (IQ) was assessed in a 17-segment coronary model using attenuation values (HU), contrast-to-noise (CNR), signal-to-noise ratio (SNR) (objective IQ) and a Likert scale (subjective IQ: 1 = poor/2 = sufficient/3 = good/4 = excellent). ig. Patient distribution was: n = 60 for 70kV, n = 37 80kV and n = 17 90kV. Mean BV was 5.4±0.6L for men and 4.1±0.6L for women. Mean CM volume (300 mg I/mL) and flow rate were: 30.9±6.4mL and 3.3±0.5mL/s (70kV); 40.8±7.1mL and 4.5±0.6mL/s (80kV); 53.6±8.6mL and 5.7±0.6mL/s (90kV). Overall mean HU was >300HU in 98.2% (112/114) of patients. Overall mean attenuation was below 300HU in two scans (70kV) due to late scan timing. Of 1.661 segments, 95.4% was assessable. Mean CNR was 14±4(70kV), 13±3(80kV) and 14±4(90kV); mean SNR was 10±2(both 70kV+80kV) and 9±2(90kV). Objective IQ was comparable between kV settings, protocols and sex. Subjective IQ was diagnostic in all scans and excellent-sufficient in 95.4% of segments. Personalisation of CCTA CM injection protocols to BV and ATVS is a promising technique to tailor CM administration to the individual patient, while maintaining diagnostic IQ.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Competing Interests: The authors have read the journal's policy and have the following conflicts: MD receives institutional grants from Philips, Siemens and Bayer and personal fees (speakers bureau) from Cook, Siemens, and Bayer. JEW reports institutional research grants from Philips, AGFA, GE, BRACCO, Siemens and Bayer and personal fees (speakers bureau) from Siemens and Bayer. This does not alter our adherence to all the PLOS ONE policies on sharing data and materials.
ISSN:1932-6203
1932-6203