Artifacts in cranial MRI caused by extracranial foreign bodies and analysis of these foreign bodies

Abstract Purpose : The purpose of our study was to conduct a chemical analysis of extracranial foreign bodies (FBs) causing artifacts in cranial magnetic resonance imaging (MRI) and to investigate the association between chemical composition, magnetic susceptibility, and artifact size. Materials and...

Full description

Saved in:
Bibliographic Details
Published inThe Indian journal of radiology & imaging Vol. 29; no. 3; pp. 299 - 304
Main Authors Kayaci, Selim, Tabak, Ahmet, Durur-Subasi, Irmak, Eldes, Tugba, Koksal, Vaner, Sirin, Murat, Arslan, Yusuf Kemal
Format Journal Article
LanguageEnglish
Published A-12, Second Floor, Sector -2, NOIDA -201301, India Thieme Medical and Scientific Publishers Private Ltd 01.07.2019
Wolters Kluwer India Pvt. Ltd
Georg Thieme Verlag Stuttgart
Wolters Kluwer - Medknow
Thieme Medical and Scientific Publishers Pvt. Ltd
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Purpose : The purpose of our study was to conduct a chemical analysis of extracranial foreign bodies (FBs) causing artifacts in cranial magnetic resonance imaging (MRI) and to investigate the association between chemical composition, magnetic susceptibility, and artifact size. Materials and Methods : A total of 12 patients were included in the study. The FBs responsible for the artifacts were visualized using cranial computed tomography (CT). Artifact-causing FBs were removed from the scalps of 10 patients and analyzed using scanning electron microscope with energy dispersive spectroscopy (SEM-EDS), X-ray diffraction spectroscopy (X-RD), and Fourier-transform infrared spectroscopy (FT-IR). The magnetic susceptibility of the samples was determined using the reference standard material MnCl 2 .6H 2 O. The volume of the MRI artifacts was measured in cubic centimeters (cm 3 ). Results : EDS results demonstrated that the mean Fe ratio was 5.82% in the stone samples and 0.08% in the glass samples. Although no phase peaks were detected in the X-RD spectra of the glass samples, peaks of Fe 2 O 3 , Al 2 Ca (SiO 4 ) were detected in the X-RD spectra of the stone samples. The FT-IR spectra revealed metal oxide peaks corresponding to Fe, Al, in the stone samples and peaks confirming Al 2 SiO 5 and Na 2 SiO 3 structures in the glass samples. The mean volumes of the MRI artifacts produced by the stone and glass samples were 5.9 cm 3 and 2.5 cm 3 , respectively. Conclusions : Artifacts caused by extracranial FBs containing metal/metal oxide components are directly associated with their chemical composition and the artifact size are also related to element composition and magnetic susceptibility.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0971-3026
0971-3026
1998-3808
DOI:10.4103/ijri.IJRI_211_18