Successful Removal of a Foreign Body Located in the Peripheral Airway Using Flexible Bronchoscopy with Virtual Bronchoscopy Navigation
A case in which a foreign body located in the peripheral airway of the lung was removed by flexible bronchoscopy using a virtual bronchoscopy navigation (VBN) system has been reported. The patient was a 60-year-old man. Chest radiography revealed an incidental foreign body in the left lower lung. Ch...
Saved in:
Published in | Internal Medicine Vol. 63; no. 10; pp. 1439 - 1442 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Japan
The Japanese Society of Internal Medicine
15.05.2024
Japan Science and Technology Agency |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A case in which a foreign body located in the peripheral airway of the lung was removed by flexible bronchoscopy using a virtual bronchoscopy navigation (VBN) system has been reported. The patient was a 60-year-old man. Chest radiography revealed an incidental foreign body in the left lower lung. Chest computed tomography with 1.0-mm slices was used to create a VBN system and confirm the foreign body in left B9biiαy, which was removed by flexible bronchoscopy. Thus, peripheral foreign bodies can be safely removed using flexible bronchoscopy by creating a VBN system in advance. |
---|---|
Bibliography: | ObjectType-Case Study-2 SourceType-Scholarly Journals-1 ObjectType-Feature-4 content type line 23 ObjectType-Report-1 ObjectType-Article-3 Correspondence to Dr. Toshiyuki Nakai, tnakai8716@gmail.com |