Algorithms for Monitoring Heart Rate and Respiratory Rate From the Video of a User's Face

Smartphone cameras can measure heart rate (HR) by detecting pulsatile photoplethysmographic (iPPG) signals from post-processing the video of a subject's face. The iPPG signal is often derived from variations in the intensity of the green channel as shown by Poh et. al. and Verkruysse et. al.. I...

Full description

Saved in:
Bibliographic Details
Published inIEEE journal of translational engineering in health and medicine Vol. 6; pp. 1 - 11
Main Authors Sanyal, Shourjya, Nundy, Koushik Kumar
Format Journal Article
LanguageEnglish
Published United States IEEE 01.01.2018
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Smartphone cameras can measure heart rate (HR) by detecting pulsatile photoplethysmographic (iPPG) signals from post-processing the video of a subject's face. The iPPG signal is often derived from variations in the intensity of the green channel as shown by Poh et. al. and Verkruysse et. al.. In this pilot study, we have introduced a novel iPPG method where by measuring variations in color of reflected light, i.e., Hue, and can therefore measure both HR and respiratory rate (RR) from the video of a subject's face. This paper was performed on 25 healthy individuals (Ages 20-30, 15 males and 10 females, and skin color was Fitzpatrick scale 1-6). For each subject we took two 20 second video of the subject's face with minimal movement, one with flash ON and one with flash OFF. While recording the videos we simultaneously measuring HR using a Biosync B-50DL Finger Heart Rate Monitor, and RR using self-reporting. This paper shows that our proposed approach of measuring iPPG using Hue (range 0-0.1) gives more accurate readings than the Green channel. HR/Hue (range 0-0.1) (r = 0.9201,p-value = 4.1617, and RMSE = 0.8887) is more accurate compared with HR/Green (r = 0.4916,p-value = 11.60172, and RMSE = 0.9068). RR/Hue (range 0-0.1) (r = 0.6575, p-value = 0.2885, and RMSE = 3.8884) is more accurate compared with RR/Green (r = 0.3352, p-value = 0.5608, and RMSE = 5.6885). We hope that this hardware agnostic approach for detection of vital signals will have a huge potential impact in telemedicine, and can be used to tackle challenges, such as continuous non-contact monitoring of neo-natal and elderly patients. An implementation of the algorithm can be found at https://pulser.thinkbiosolution.com
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:2168-2372
2168-2372