Movement therapy in advanced heart failure assisted by a lightweight wearable robot: a feasibility pilot study

Aims The aim of this pilot study was to investigate the safety, feasibility, tolerability, and acceptability of an assisted mobilization of advanced heart failure patients, using a lightweight, exoskeleton‐type robot (Myosuit, MyoSwiss AG, Zurich, Switzerland). Methods and results Twenty patients in...

Full description

Saved in:
Bibliographic Details
Published inESC Heart Failure Vol. 9; no. 3; pp. 1643 - 1650
Main Authors Just, Isabell Anna, Fries, Denis, Loewe, Sina, Falk, Volkmar, Cesarovic, Nikola, Edelmann, Frank, Feuerstein, Anna, Haufe, Florian L., Xiloyannis, Michele, Riener, Robert, Schoenrath, Felix
Format Journal Article
LanguageEnglish
Published England John Wiley & Sons, Inc 01.06.2022
John Wiley and Sons Inc
Wiley
Subjects
Online AccessGet full text
ISSN2055-5822
2055-5822
DOI10.1002/ehf2.13903

Cover

Loading…
More Information
Summary:Aims The aim of this pilot study was to investigate the safety, feasibility, tolerability, and acceptability of an assisted mobilization of advanced heart failure patients, using a lightweight, exoskeleton‐type robot (Myosuit, MyoSwiss AG, Zurich, Switzerland). Methods and results Twenty patients in functional NYHA class III performed activities of daily life (ADL, n = 10) or participated in a single, standardized, 60 min rehabilitation exercise unit (REU, n = 10) with and without the Myosuit. The outcome assessment included the evaluation of vital signs, adverse events, rates of perceived exertion and dyspnoea (RPE, RPD), the ability to perform ADL or REU, and the individual acceptability. The mean age of the subjects was 49.4 (±11.0) years; 80% were male. The mean left ventricular ejection fraction was 22.1% (±7.4%) and the median NT‐proBNP 2054 pg/mL (IQR 677, 3270 pg/mL). In all patients, mobilization with the Myosuit was feasible independently or with minor support. The mean individual difference in the total walking distance of the patients without and with robotic assistance was −26.5 m (95% confidence interval (CI) −142 to 78 m, P = 0.241). No adverse events occurred. RPE and RPD showed no significant difference with or without the device (ADL: RPE −0.1 m, 95% CI −1.42 to 1.62, P = 0.932 and RPD −0.95 m, 95% CI −0.38 to 2.28, P = 0.141; REU: RPE 1.1 m, 95% CI −2.90 to 0.70, P = 0.201 and RPD 0.5 m, 95% CI −2.02 to 1.02, P = 0.435). All median responses in the acceptability questionnaire were positive. The patients felt safe and enjoyed the experience; 85% would be interested in participating in robot‐assisted training on a regular basis. Conclusion This feasibility pilot trial provides first indications that a robotic exoskeleton‐assisted mobilization of patients with advanced heart failure is safe, feasible, well‐tolerated, and well‐accepted. The results are highly encouraging to further pursue this innovative approach in rehabilitation programmes. This trial was registered at ClinicalTrials.gov: NCT04839133.
Bibliography:These authors contributed equally to this work.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
ISSN:2055-5822
2055-5822
DOI:10.1002/ehf2.13903