A model-based reconstruction for undersampled radial spin-echo DTI with variational penalties on the diffusion tensor

Radial spin‐echo diffusion imaging allows motion‐robust imaging of tissues with very low T2 values like articular cartilage with high spatial resolution and signal‐to‐noise ratio (SNR). However, in vivo measurements are challenging, due to the significantly slower data acquisition speed of spin‐echo...

Full description

Saved in:
Bibliographic Details
Published inNMR in biomedicine Vol. 28; no. 3; pp. 353 - 366
Main Authors Knoll, Florian, Raya, José G., Halloran, Rafael O., Baete, Steven, Sigmund, Eric, Bammer, Roland, Block, Tobias, Otazo, Ricardo, Sodickson, Daniel K.
Format Journal Article
LanguageEnglish
Published England Blackwell Publishing Ltd 01.03.2015
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Radial spin‐echo diffusion imaging allows motion‐robust imaging of tissues with very low T2 values like articular cartilage with high spatial resolution and signal‐to‐noise ratio (SNR). However, in vivo measurements are challenging, due to the significantly slower data acquisition speed of spin‐echo sequences and the less efficient k‐space coverage of radial sampling, which raises the demand for accelerated protocols by means of undersampling. This work introduces a new reconstruction approach for undersampled diffusion‐tensor imaging (DTI). A model‐based reconstruction implicitly exploits redundancies in the diffusion‐weighted images by reducing the number of unknowns in the optimization problem and compressed sensing is performed directly in the target quantitative domain by imposing a total variation (TV) constraint on the elements of the diffusion tensor. Experiments were performed for an anisotropic phantom and the knee and brain of healthy volunteers (three and two volunteers, respectively). Evaluation of the new approach was conducted by comparing the results with reconstructions performed with gridding, combined parallel imaging and compressed sensing and a recently proposed model‐based approach. The experiments demonstrated improvements in terms of reduction of noise and streaking artifacts in the quantitative parameter maps, as well as a reduction of angular dispersion of the primary eigenvector when using the proposed method, without introducing systematic errors into the maps. This may enable an essential reduction of the acquisition time in radial spin‐echo diffusion‐tensor imaging without degrading parameter quantification and/or SNR. Copyright © 2015 John Wiley & Sons, Ltd. Radial spin‐echo diffusion imaging allows motion‐robust imaging of tissues with very low T2 values. This work introduces a new reconstruction approach for undersampled DTI that combines model‐based reconstruction and compressed sensing. Experiments were performed for an anisotropic phantom and the knee and brain of healthy volunteers. Improvements were observed in terms of reduction of noise and streaking artifacts in the quantitative parameter maps, as well as a reduction of angular dispersion of the primary eigenvector.
Bibliography:ark:/67375/WNG-ZV6KXB99-0
istex:CC5BD18670274063DC7C5A729B9CB0C7009A04E7
NIH - No. P41 EB017183; No. R01 EB00047; No. R01 EB8706; No. R21 AR066897
ArticleID:NBM3258
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
These authors contributed equally to this work.
ISSN:0952-3480
1099-1492
DOI:10.1002/nbm.3258