Quantitative analysis of velopharyngeal movement using a stereoendoscope: accuracy and reliability of range images

Objective: We developed a novel method of producing accurate range images of the velopharynx using a three-dimensional (3D) endoscope to obtain detailed measurements of velopharyngeal movements. The purpose of the present study was to determine the relationship between the distance from the endoscop...

Full description

Saved in:
Bibliographic Details
Published inComputer Aided Surgery Vol. 20; no. 1; pp. 29 - 33
Main Authors Nakano, Asuka, Mishima, Katsuaki, Shiraishi, Ruriko, Ueyama, Yoshiya
Format Journal Article
LanguageEnglish
Published England Taylor & Francis 02.01.2015
Informa UK Limited
Subjects
Online AccessGet full text
ISSN1092-9088
1097-0150
1097-0150
DOI10.3109/10929088.2015.1076041

Cover

More Information
Summary:Objective: We developed a novel method of producing accurate range images of the velopharynx using a three-dimensional (3D) endoscope to obtain detailed measurements of velopharyngeal movements. The purpose of the present study was to determine the relationship between the distance from the endoscope to an object, elucidate the measurement accuracy along the temporal axes, and determine the degree of blurring when using a jig to fix the endoscope. Methods: An endoscopic measuring system was developed in which a pattern projection system was incorporated into a commercially available 3D endoscope. After correcting the distortion of the camera images, range images were produced using pattern projection to achieve stereo matching. Graph paper was used to measure the appropriate distance from the camera to an object, the mesial buccal cusp of the right maxillary first molar was measured to clarify the range image stability, and an electric actuator was used to evaluate the measurement accuracy along the temporal axes. Results: The measurement error was substantial when the distance from the camera to the subject was >6.5 cm. The standard error of the 3D coordinate value produced from 30 frames was within 0.1 mm (range, 0.01-0.08 mm). The measurement error of the temporal axes was 9.16% in the horizontal direction and 9.27% in the vertical direction. Conclusion: The optimal distance from the camera to an object is <6.5 cm. The present endoscopic measuring system can provide stable range images of the velopharynx when using an appropriate fixation method and enables quantitative analysis of velopharyngeal movements.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1092-9088
1097-0150
1097-0150
DOI:10.3109/10929088.2015.1076041