Inhomogeneous vasodilatory responses of rat tail arteries to heat stress: evaluation by synchrotron radiation microangiography

Tail blood flow is crucial for dissipating body heat in rats. Angiographies are convenient tools to evaluate tail circulation. However, conventional angiographies do not have sufficient sensitivity or spatial resolution for small vessels. Recently, we developed a novel microangiographic system using...

Full description

Saved in:
Bibliographic Details
Published inJapanese journal of physiology Vol. 52; no. 5; p. 403
Main Authors Kuwabara, Eriko, Furuyama, Fujiya, Ito, Kunihisa, Tanaka, Etsuro, Hattan, Naoichiro, Fujikura, Hisanori, Kimura, Koji, Goto, Takako, Hayashi, Takashi, Taira, Hiroyuki, Shinozaki, Yoshiro, Umetani, Keiji, Hyodo, Kazuyuki, Tanioka, Kenkichi, Mochizuki, Ryo, Kawai, Toshiaki, Koide, Shirosaku, Mori, Hidezo
Format Journal Article
LanguageEnglish
Published Japan 01.10.2002
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:Tail blood flow is crucial for dissipating body heat in rats. Angiographies are convenient tools to evaluate tail circulation. However, conventional angiographies do not have sufficient sensitivity or spatial resolution for small vessels. Recently, we developed a novel microangiographic system using monochromatic synchrotron radiation and a high-definition video camera system. Here, we report an evaluation of rat tail circulation under heat stress using the synchrotron radiation microangiographic system. We performed an experiment using the microangiography of the caudal artery before and after heating up WKAH/HkmSlc rats to rectal temperature of 39 degrees C. The images were digitized and temporal subtraction was performed, and the diameters of caudal arteries were evaluated. After heating, the medial caudal artery was markedly dilated (320 +/- 53 to 853 +/- 243 micro m in diameter, p<0.001), while no significant change was observed in the lateral caudal arteries (139 +/- 42 to 167 +/- 73 micro m) and segmental anastomosing vessels. The heat stress allowed for visualization of the superficial caudal arteries with a diameter of approximately 60 micro m, not visible prior to heating. Thus, synchrotron radiation microangiography demonstrated that the rat tail possessed dual sets of arteries; one set was highly sensitive to heat-induced vasodilation (medial caudal artery and superficial caudal arteries) and the other set was less sensitive (lateral caudal arteries and segmental anastomosing vessels).
ISSN:0021-521X
DOI:10.2170/jjphysiol.52.403