Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials test...

Full description

Saved in:
Bibliographic Details
Published inJournal of applied oral science Vol. 24; no. 3; pp. 258 - 263
Main Authors ABDULLAH, Adil Othman, TSITROU, Effrosyni A, POLLINGTON, Sarah
Format Journal Article
LanguageEnglish
Published Brazil Faculdade De Odontologia De Bauru - USP 01.05.2016
University of São Paulo
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (P<0.001). The average internal fit was: VITA CAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p<0.001). However, the mode of fracture showed no differences between the groups (p>0.05). CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1678-7757
1678-7765
1678-7757
1678-7765
DOI:10.1590/1678-775720150451