Detection of pneumonia associated pathogens using a prototype multiplexed pneumonia test in hospitalized patients with severe pneumonia

Severe pneumonia remains an important cause of morbidity and mortality. Polymerase chain reaction (PCR) has been shown to be more sensitive than current standard microbiological methods--particularly in patients with prior antibiotic treatment--and therefore, may improve the accuracy of microbiologi...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 9; no. 11; p. e110566
Main Authors Schulte, Berit, Eickmeyer, Holm, Heininger, Alexandra, Juretzek, Stephanie, Karrasch, Matthias, Denis, Olivier, Roisin, Sandrine, Pletz, Mathias W, Klein, Matthias, Barth, Sandra, Lüdke, Gerd H, Thews, Anne, Torres, Antoni, Cillóniz, Catia, Straube, Eberhard, Autenrieth, Ingo B, Keller, Peter M
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 14.11.2014
Public Library of Science (PLoS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Severe pneumonia remains an important cause of morbidity and mortality. Polymerase chain reaction (PCR) has been shown to be more sensitive than current standard microbiological methods--particularly in patients with prior antibiotic treatment--and therefore, may improve the accuracy of microbiological diagnosis for hospitalized patients with pneumonia. Conventional detection techniques and multiplex PCR for 14 typical bacterial pneumonia-associated pathogens were performed on respiratory samples collected from adult hospitalized patients enrolled in a prospective multi-center study. Patients were enrolled from March until September 2012. A total of 739 fresh, native samples were eligible for analysis, of which 75 were sputa, 421 aspirates, and 234 bronchial lavages. 276 pathogens were detected by microbiology for which a valid PCR result was generated (positive or negative detection result by Curetis prototype system). Among these, 120 were identified by the prototype assay, 50 pathogens were not detected. Overall performance of the prototype for pathogen identification was 70.6% sensitivity (95% confidence interval (CI) lower bound: 63.3%, upper bound: 76.9%) and 95.2% specificity (95% CI lower bound: 94.6%, upper bound: 95.7%). Based on the study results, device cut-off settings were adjusted for future series production. The overall performance with the settings of the CE series production devices was 78.7% sensitivity (95% CI lower bound: 72.1%) and 96.6% specificity (95% CI lower bound: 96.1%). Time to result was 5.2 hours (median) for the prototype test and 43.5 h for standard-of-care. The Pneumonia Application provides a rapid and moderately sensitive assay for the detection of pneumonia-causing pathogens with minimal hands-on time. Deutsches Register Klinischer Studien (DRKS) DRKS00005684.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
Conceived and designed the experiments: BS JW HE SJ M. Karrasch OD SR MWP M. Klein SB GHL A. Thews A. Torres CC ES IBA PMK. Performed the experiments: BS SJ OD SR M. Karrasch SB GHL A. Torres CC PMK. Analyzed the data: BS JW SJ M. Karrasch OD SR MWP M. Klein SB GHL A. Thews A. Torres ES IBA PMK. Contributed reagents/materials/analysis tools: BS JW HE AH SJ M. Karrasch OD SR M. Klein SB GHL A. Thews A. Torres CC PMK. Wrote the paper: BS JW M. Karrasch OD SR MWP M. Klein SB GHL A. Thews A. Torres CC ES IBA PMK.
Competing Interests: B.S., M.Ka., E.S., and P.M.K. have obtained travel grants by Curetis. M.Kl., S.B., G.H.L., and A.T. are employees of Curetis. The device described in this paper is a device in development by Curetis. There are no patents, products in development or marketed products to declare. This does not alter the authors' adherence to all PLOS ONE policies on sharing data and materials.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0110566