Evaluation of Different Registration Algorithms to Reduce Motion Artifacts in CT-Thermography (CTT)

Computed tomography (CT)-based Thermography (CTT) is currently being investigated as a non-invasive temperature monitoring method during ablation procedures. Since multiple CT scans with defined time intervals were acquired during this procedure, interscan motion artifacts can occur between the imag...

Full description

Saved in:
Bibliographic Details
Published inDiagnostics (Basel) Vol. 13; no. 12; p. 2076
Main Authors Kostyrko, Bogdan, Rubarth, Kerstin, Althoff, Christian, Zibell, Miriam, Neizert, Christina Ann, Poch, Franz, Torsello, Giovanni Federico, Gebauer, Bernhard, Lehmann, Kai, Niehues, Stefan Markus, Mews, Jürgen, Diekhoff, Torsten, Pohlan, Julian
Format Journal Article
LanguageEnglish
Published Switzerland MDPI AG 01.06.2023
MDPI
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Computed tomography (CT)-based Thermography (CTT) is currently being investigated as a non-invasive temperature monitoring method during ablation procedures. Since multiple CT scans with defined time intervals were acquired during this procedure, interscan motion artifacts can occur between the images, so registration is required. The aim of this study was to investigate different registration algorithms and their combinations for minimizing inter-scan motion artifacts during thermal ablation. Four CTT datasets were acquired using microwave ablation (MWA) of normal liver tissue performed in an in vivo porcine model. During each ablation, spectral CT volume scans were sequentially acquired. Based on initial reconstructions, rigid or elastic registration, or a combination of these, were carried out and rated by 15 radiologists. Friedman's test was used to compare rating results in reader assessments and revealed significant differences for the ablation probe movement rating only ( = 0.006; range, 5.3-6.6 points). Regarding this parameter, readers assessed rigid registration as inferior to other registrations. Quantitative analysis of ablation probe movement yielded a significantly decreased distance for combined registration as compared with unregistered data. In this study, registration was found to have the greatest influence on ablation probe movement, with connected registration being superior to only one registration process.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2075-4418
2075-4418
DOI:10.3390/diagnostics13122076