Quantitative evaluation of upper urinary tract pump function in pigs with acute unilateral lower ureteral obstruction by 640-slice dynamic volume CT

It is a challenging problem to differentiate obstructive hydronephrosis from noninvasive evaluation of renal pelvis and ureteral motility in patients. The purpose of this study was to explore the value of 640-slice dynamic volume CT (DVCT) in the quantitative measurement of upper urinary tract (UUT)...

Full description

Saved in:
Bibliographic Details
Published inBMC urology Vol. 21; no. 1; p. 118
Main Authors Mao, Chongwen, Peng, Cong, Li, Song, Chen, Liling, You, Mengjing, Fang, Kewei, Xiang, Shutian, Su, Yunshan
Format Journal Article
LanguageEnglish
Published England BioMed Central Ltd 02.09.2021
BioMed Central
BMC
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:It is a challenging problem to differentiate obstructive hydronephrosis from noninvasive evaluation of renal pelvis and ureteral motility in patients. The purpose of this study was to explore the value of 640-slice dynamic volume CT (DVCT) in the quantitative measurement of upper urinary tract (UUT) pump function after acute unilateral lower ureteral obstruction in pigs. In this study, a perfusion pig model was constructed by constant pressure perfusion testing of the renal pelvis and left nephrostomy. The perfusion and pressure measuring devices were connected to create a state of no obstruction and acute obstruction of the lower part of the left ureter. After successful modelling, continuous dynamic volume scanning of the bilateral renal excretion phase was performed with 640-slice DVCT, and pump functions of the renal pelvis and part of the upper ureter were calculated and analysed. No obstruction or acute obstruction of the lower part of the left ureter was observed. Pump functions of the renal pelvis and part of the upper ureter were determined. The results showed that after LUUT fistulostomy, the time difference between the average UUT volume and positive volume value increased gradually, and the calculated flow velocity decreased, which was significantly different from that of the RUUT. The volume difference of the LUUT increased significantly in mild obstruction. In the bilateral control, the volume change rate of the LUUT increased with mild obstruction and decreased with severe obstruction, and there was a significant difference between the left and right sides. The continuous dynamic volume scan and measurement of 640-slice DVCT can obtain five pump function datasets of UUT in pigs with acute lower ureteral obstruction.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1471-2490
1471-2490