Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study

Complications after total hip arthroplasty (THA) are frequently the consequence of malpositioned components or leg length discrepancy after surgery. Recently, a new version of a portable, accelerometer-based hip navigation system (New HipAlign) was made available with a change in the method of measu...

Full description

Saved in:
Bibliographic Details
Published inBMC musculoskeletal disorders Vol. 22; no. 1; p. 299
Main Authors Tanino, Hiromasa, Nishida, Yasuhiro, Mitsutake, Ryo, Ito, Hiroshi
Format Journal Article
LanguageEnglish
Published England BioMed Central Ltd 23.03.2021
BioMed Central
BMC
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Complications after total hip arthroplasty (THA) are frequently the consequence of malpositioned components or leg length discrepancy after surgery. Recently, a new version of a portable, accelerometer-based hip navigation system (New HipAlign) was made available with a change in the method of measuring cup abduction and the addition of a leg length measurement function. The purposes of this study were to investigate cup positioning and to examine the accuracy of leg length measurement with New HipAlign. Cups were implanted and intraoperative leg length change was measured using New HipAlign in 60 THAs through a posterior approach in the lateral decubitus position. The cup position and radiographic leg length change were determined postoperatively on pelvic radiograph and computed tomography scans. We previously compared cup positioning with a previous version of a portable, accelerometer-based hip navigation system (Previous HipAlign) and conventional surgical techniques. Cup positioning in this study was compared with the results of out previous study using Previous HipAlign. The mean cup abduction of 40.3° ± 4.9° (range, 26° to 53°) and the mean cup anteversion of 15.8° ± 5.6° (range, 6.7° to 29.5°) were found. The deviation of the postoperative measured angles from the target cup position was 3.7° ± 3.3° for cup abduction and 5.9° ± 3.6° for cup anteversion. 56/60 of the cups were inside the Lewinnek safe zone. Compared with our previous study using Previous HipAlign, there were no significant differences with regard to cup abduction, cup anteversion, the deviation from the target cup position for cup abduction, the value of deviation for cup anteversion, and the number of cups inside the Lewinnek safe zone (P = 0.218, 0.334, 0.651, 0.797, 0.592). The mean difference between the intraoperative and radiographic leg length changes was + 0.8 ± 3.4 mm. There was significant correlation between the intraoperative and radiographic leg length changes (r = 0.804, P = 0.000). Use of New HipAlign allowed for accurate cup placement and reliable leg length measurement during THA. Clinical trial is defined as 'any research study that prospectively assigns human participants or groups of humans to one or more health-related interventions to evaluate the effects on health outcome' by the World Health Organization (WHO). Because this study is not a clinical trial, trial registration is not needed.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1471-2474
1471-2474
DOI:10.1186/s12891-021-04167-y