Quantitation of mitral valve tenting in ischemic mitral regurgitation by transthoracic real-time three-dimensional echocardiography

We sought to investigate the geometric changes of the mitral leaflets and annulus, clarify the maximum tenting site of the leaflets, and quantify the valve tenting in ischemic mitral regurgitation (MR) using three-dimensional (3D) echocardiography. Although the understanding of the mechanisms of isc...

Full description

Saved in:
Bibliographic Details
Published inJournal of the American College of Cardiology Vol. 45; no. 5; pp. 763 - 769
Main Authors Watanabe, Nozomi, Ogasawara, Yasuo, Yamaura, Yasuko, Kawamoto, Takahiro, Toyota, Eiji, Akasaka, Takashi, Yoshida, Kiyoshi
Format Journal Article
LanguageEnglish
Published New York, NY Elsevier Inc 01.03.2005
Elsevier Science
Elsevier Limited
Subjects
Online AccessGet full text
ISSN0735-1097
1558-3597
DOI10.1016/j.jacc.2004.11.048

Cover

More Information
Summary:We sought to investigate the geometric changes of the mitral leaflets and annulus, clarify the maximum tenting site of the leaflets, and quantify the valve tenting in ischemic mitral regurgitation (MR) using three-dimensional (3D) echocardiography. Although the understanding of the mechanisms of ischemic MR has advanced recently, the geometric changes of the mitral leaflets and annulus have been assessed by two-dimensional echocardiography in the clinical setting, despite the unique configuration of the leaflets and annulus. Utilizing real-time 3D echocardiography, we obtained transthoracic volumetric images in 12 patients with ischemic MR presenting with global left ventricular dysfunction and in 10 controls. Original software was used to crop the 3D data into 18 radial planes, and we marked the mitral annulus and leaflets in each plane in mid-systole. The 3D images of the leaflets and annulus were reconstructed for the quantitative measurements. In ischemic MR, the annulus flattened with apparent tenting of the leaflets. Maximum and mean tenting length were longer and tenting volume was larger in ischemic MR than control subjects (maximum tenting length: 9.8 ± 2.0 mm vs. 3.1 ± 1.2 mm, p < 0.0001, mean tenting length: 3.7 ± 0.9 mm vs. 0.7 ± 0.5 mm, p < 0.0001, tenting volume: 4.09 ± 1.22 ml vs. 0.45 ± 0.29 ml, p < 0.0001). The maximum tenting site was located in anterior leaflet in all patients. We clearly demonstrated 3D geometric deformity of the mitral leaflets and annulus in ischemic MR using novel software for creating images by 3D echocardiography. This technique will be helpful in making a proper decision for the surgical strategy in each patient.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0735-1097
1558-3597
DOI:10.1016/j.jacc.2004.11.048